Egtvkhkecvkqpu"Kphqtocvkqp"
C05"
Vmax = 30 Vdc, Imax = 110 mA, Ci = 8 nF, Li = 12 uH
Temperature Class T4
Maximum Ambient Temperature: 60ºC (-20 to 60 ºC)
NEMKO (Norges Elektriske MaterielKontroll)
Explosion Proof
(NEMKO 00ATEX305X)
Group II, Category 2 G, Ex d, Group IIC, Temperature Class T6, EPL Gb
Ambient Temperature: -20ºC
≤
Ta
≤
+60ºC
Working Pressure: 20-100 psi
Environmental Protection
(NEMKO 00ATEX305X)
Options: IP66W or IP66
Special conditions for safe use:
Repairs of the flameproof joints must be made in compliance with the structural specifications provided by the manufacturer.
Repairs must not be made on the basis of values specified in tables 1 and 2 of EN/IEC 60079-1.
The Essential Health and Safety Requirements are assured by compliance with:
EN 60079-0:2012 General Requirements
EN 60079-1:2007 Flameproof Enclosures “d”
EXAM (BBG Prüf - und Zertifizier GmbH)
Intrinsic Safety
(DMT 01 ATEX E 012)
Group II, Category 2 G, Ex d [ia], Group IIC, Temperature Class T6, EPL Gb
Supply and signal circuit for the connection to an intrinsically safe 4-20mA current loop
Ui = 28 Vdc, Ii = 93 mA, Pi = 700 mW, Ci
≤
5 nF Li = Neg
Ambient Temperature: -20ºC
≤
Ta
≤
+60ºC
The Essential Health and Safety Requirements are assured by compliance with:
EN 60079-0:2012 +A11:2013 General Requirements
EN 60079-1:2007 Flameproof Enclosures “d”
EN 60079-11:2012 Intrinsic Safety “i”
CEPEL (Centro de Pesquisa de Energia Elétrica)
Intrinsic Safety
(CEPEL 00.0017)
Ex d ia, Group IIC, Temperature Class T5/T6, EPL Gb
Entity Parameters:
Pi = 0.7 W, Ui = 30 V, Ii = 100 mA, Ci = 6.4 nF, Li = Neg
Ambient Temperature:
-20 to 65 ºC for T5
-20 to 40 ºC for T6
Protection by enclosure
(CEPEL 00.0017)
Ex tb, Group IIIC, Temperature Class T100ºC/T85ºC, EPL Db
Ambient Temperature:
-20 to 65 ºC for T100ºC
-20 to 40 ºC for T85ºC
Explosion Proof
(CEPEL 98.0008)
Ex d, Group IIC, Temperature Class T6, EPL Gb
Maximum Ambient Temperature: 40ºC (-20 to 40 ºC)
Protection by enclosure
(CEPEL 98.0008)
Ex tb, Group IIIC, Temperature Class T85ºC, EPL Db
Содержание FY301
Страница 8: ...H 523 Qrgtcvkqp Ockpvgpcpeg cpf Kpuvtwevkqpu Ocpwcn XKKK...
Страница 24: ...FY301 Operation Maintenance and Instructions Manual 1 16...
Страница 54: ...H 523 Qrgtcvkqp Ockpvgpcpeg cpf Kpuvtwevkqpu Ocpwcn 7038...
Страница 64: ...H 523 Qrgtcvkqp Ockpvgpcpeg cpf Kpuvtwevkqpu Ocpwcn C08 CEPEL Centro de Pesquisa de Energia El trica...
Страница 65: ...Egtvkhkecvkqpu Kphqtocvkqp C09 Eqpvtqn Ftcykpi FM Approvals Factory Mutual...
Страница 66: ...H 523 Qrgtcvkqp Ockpvgpcpeg cpf Kpuvtwevkqpu Ocpwcn C0 CSA Canadian Standards Association...
Страница 82: ...6 Mounting Instructions...