Installation and Sensitivity Adjustment

Install the detector on the ceiling or walls adjacent or opposite to 
the protected glass. Avoid proximity to noisy objects such as bells, 
fans, compressors, and loud machinery. Make sure the microphone 
has a direct and unobstructed view of the protected glass.

Installation steps:

1. 

Connect the AC adaptor with the connector of the detector. Then 
plug the AC adaptor into wall socket.

2. 

Clean the surface of the locations you are going to install.

3. 

Use the double-sided tape to fix the product on the installation site.

You can set sensitivity of detector based on requirements. If the 
environment produces echoes easily, adjust sensitivity to low; if the 
environment has damping materials, adjust the sensitivity to high.

Installation Diagram

Connect with the Control Panel

Please connect the detector with control panel before use:

Make sure the control panel is under connecting state. Press the 
rear tamper switch of the detector, the control panel receives 
wireless signals from the detector and beeps once. Connection 
succeeded. Arm the alarm system and trigger the rear tamper 
switch of the detector again, the siren of control panel will hoot to 
indicate they have been connected successfully.

Specifications

Power Supply:

 DC 12 V 500 mA

Static Current:

 < 2.6 mA

Alarm Current:

 < 28 mA

Detection Distance: 

Max. 7 m

Transmitting Distance:

 < 80 m (in open area)

Radio Frequency:

 868 MHz or 915 MHz

Housing Material:

 ABS plastic

Operating Condition:

Temperature: -10 °C ~ + 55 °C

Relative Humidity: < 80% (non-condensing)

Detector Dimensions (L x W x H):

 54 X 15 X 106.5 mm

Содержание GB1260

Страница 1: ...2015 SMANOS HOLDING LTD All Rights Reserved Printed in China Ver GB1260 UM EN DE FR NL V1 0 MULT ILI NG UAL U S E R M A N U A L EN DE FR NL GB1260 Glass Break Detector...

Страница 2: ...duct Overview Front View Rear View Sound Pickup Hole LED Indicator Connector for AC Adapter External Tamper Switch Interior View AC Adaptor LED Indicator Zone Setting Antenna Audio Sensor Sensitivity...

Страница 3: ...the environment has damping materials adjust the sensitivity to high Installation Diagram Connect with the Control Panel Please connect the detector with control panel before use Make sure the contro...

Страница 4: ...g Antenne Audiosensor Empfindlichk eitseinstellung Interner Sabotagekontakt Testen Verbinden Sie den Adapter mit dem Stecker und stecken Sie dann das Netzteil in die Steckdose Der Melder wechselt in d...

Страница 5: ...rbinden Sie den Melder vor Gebrauch mit dem Bedienfeld Achten Sie darauf dass das Bedienfeld im Verbindungsstatus ist Dr cken Sie auf den hinteren Sabotagekontakt des Melders das Bedienfeld empf ngt F...

Страница 6: ...secteur Indicateur lumineux R glage de zone Antenne Capteur audio R glage de la sensibilit Contact anti sabotage interne Test Branchez l adaptateur avec le connecteur puis l adaptateur une prise lectr...

Страница 7: ...c le tableau de commande avant utilisation V rifiez que le tableau de commande est en mode d attente de connexion Appuyez sur le contact anti sabotage au dos du d tecteur le tableau de commande re oit...

Страница 8: ...ooraanzicht Achteraanzicht Geluidsingang LED indicator Connector voor AC adapter Externe sabotageschakelaar Binnenzijde AC adapter LED indicator Zone instellen Antenne Audiosensor Gevoeligheid aanpass...

Страница 9: ...dempende materialen bevat stel dan de gevoeligheid op hoog in Installatiediagram Verbinden met het bedieningspaneel Verbind v r gebruik de detector met het bedieningspaneel Zorg ervoor dat het bedieni...

Отзывы: