32
3.10
Motor Quick Stop
This function is used to disable the drive function. The control word object with value 2 is used to
enable quick stop. For further information on quick stop refer to Embedded Motion controller library
document
https://www.smac-mca.com/lcc-single-axis-brushless-controller-p-
To verify, if the quick stop has been completed, check the statusword object for bit 5. It should be 0.
Use MSG instruction at RS Logix 5000 and use the instance (24640), attribute 0, value is 2 and length
is 2.