6 Saving Data and Updating Firmware
SMA Solar Technology AG
44
SI80H-BE-BEN120810
Operating Manual
Structure of the files:
The files are CSV files, which means that the data is saved as text. The files are structured as follows:
• The first lines in the file are used for information. Information lines start and end with the
character #.
• The data in the following lines is separated by semicolons.
• Decimal places are separated by full stops.
• The date format is dd/mm/yyyy.
• The time format is hh:mm:ss.
• Some of the parameter values are saved with plain text numbers (see the technical description
of the off-grid inverter for an explanation of the plain text numbers).
Requirements:
☐ A computer with installed spreadsheet software must be available.
☐ The spreadsheet software must be able to read CSV files.
1. Insert the SD card into the card reader and show the content.
2. Start the spreadsheet software and import the required file. Set the import filter in accordance
with the file structure (see spreadsheet software manual).
batstat.sma
Statistic values of the battery for evaluation by SMA Solar Technology AG
sim.ccf
System information of the off-grid inverter
bootex.log
File generated by the operating system of the computer
This file is not generated by every operating system.
File name
Explanation