6 Maintenance
SMA Solar Technology AG
Maintenance Manual
SCCP-JP-B1-WA-en-22
54
2. Vacuum the air duct from the outside or clean it with a brush.
3. Vacuum the ventilation grids or clean them with a brush.
4. Check the ventilation grids for visible damage. Replace the ventilation grids, if required.
5. Pull the front edge of the roof forward and push upward.
6. Gently push the roof to the rear. In doing so, you push the roof
out of the guide rails.
7. Check whether the air intake is soiled.
8. Clean air intake if soiled:
• Remove the grounding conductor from the inverter.
• Remove the roof and set it down on a suitable surface.
• Clean air intake with a vacuum cleaner
• Place the roof on the inverter.
• Screw the grounding conductor to the inverter (torque: 14.2 Nm).
Содержание Sunny Central 1000CP-JP
Страница 68: ...www SMA Solar com...