6 Maintenance
SMA Solar Technology AG
Maintenance Manual
51
SCCP-JP-B1-WA-en-22
6.4.2.2
Analyzing the Temperature Indicators
Depending on the type of inverter bridge, the inverter cabinet contains 8 or 17 temperature indicators which monitor
the temperature of the inverter bridges.
1 2 3
4 5 6
7 8 9
14 15 16 17
10 11 12 13
Figure 15: Position of the temperature indicators (example: inverter bridges with connection terminals at the upper end)
Position of the indicators
Type of inverter bridges
Number of indicators
1 to 17
with connection terminals at the upper
end
17
10 to 17
without connection terminals at the up-
per end
8
If the temperature exceeds a value indicated on one of the indicator fields, that field will turn black.
88
93
99
104
110
A
B
C
Figure 16: Values on an indicator (example)
Position
Description
A
The indicator field for 88°C has turned black. The temperature has reached 88°C.
B
The indicator field for 93°C has turned black. The temperature has reached 93°C. The
value 93 must be entered in the protocol.
C
The indicator field for 99°C is white. The temperature has not exceeded 99°C.
Содержание Sunny Central 1000CP-JP