Event number
Message, cause and corrective measures
9305
Unauthorized battery system
The inverter has detected an incorrect battery.
Corrective measures:
• Only operate batteries with the inverter approved by SMA Solar
Technology AG.
9306
Deviation in battery voltage
Too high a deviation between the battery and DC voltage of inverter was de-
tected.
Corrective measures:
• Make sure that the battery power cable is correctly connected.
• If this error is repeated frequently, contact Service.
9307
Battery system defective (ID [xx]
The battery has detected an internal error.
Corrective measures:
• Note the displayed error ID and look for that ID in the battery
manufacturer's error list.
• Carry out the corrective measures indicated in the battery manufacturer's
error list.
• Contact Service.
9308
Communication fault in battery system > Check battery connection
The inverter receives invalid data or no data from the battery.
Corrective measures:
• Make sure that the battery communication cable is properly connected to
the inverter as well as to the battery.
• Ensure that the battery has been approved for operation with the inverter.
• Ensure the perfect operation of the battery.
• If the battery communication cable has been properly connected and the
correct operation of the battery is ensured, contact Service.