![SMA SUNNY BOY STORAGE 2.5 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/sma/sunny-boy-storage-2-5/sunny-boy-storage-2-5_operating-manual_1294496070.webp)
9 Disconnecting the Inverter from Voltage Sources
SMA Solar Technology AG
Operating manual
SBS25-1VL-10-BE-en-13
70
9
Disconnecting the Inverter from Voltage Sources
Prior to performing any work on the inverter, always disconnect it from all voltage sources as
described in this section. Always adhere to the prescribed sequence.
Procedure:
1. Disconnect the AC circuit breaker and secure it against reconnection.
2. If the battery has a load-break switch, then switch it off (see the documentation of the battery
manufacturer).
3. Unscrew the swivel nuts from the cable glands on
the connection cap.
4. Unscrew the screws of the connection cap with a
Torx screwdriver (TX 20) and remove the connection
cap towards the bottom.
5. Ensure that no voltage is present between
L
and
N
and
L
and on the terminal block for the
AC connection using a suitable measuring device. To do so, insert the test probe (maximum
diameter: 2 mm) into each round opening of the terminal block.
6. Release and disconnect the terminal block using the
sliders located at the side.