25
5.5 Additional Connections
5.5.1 Operational Interruption
You can switch the Smart Load on and off using an external contact.
Connection Procedure
1.
Loosen the lock nut of the PG screw fitting (A) and
slide it over the cable of the load.
2.
Remove the dummy plug from the cable screw
connection.
3.
Thread the contact cable through the cable screw
connection and connect the cables to the
connection terminal "X80" (B).
4.
Tighten the lock nut on the cable screw
connection.
NOTICE!
High voltages and currents will irreparably damage the Smart Load
Observe the maximum voltage and current of the contact:
•
V
DC
= 10 V
•
I
DC
= 0.5 mA
DANGER!
Danger to life due to high voltages in the Smart Load.
•
Only start the stand-alone grid system after all work has been completed.
A
B