Event number
Message, cause and corrective measures
10341
Webconnect error: no connection
It is likely that there is an error in the network settings.
Corrective measures:
• Check the network components (DLAN, WLAN Access Point etc.).
• Ensure that the following ports are not blocked:
– Registrar: ied.sma.de:9523
– Proxy: ied.sma.de:9523
– Stun: stun.sma.de:3478
– Domain: ied.sma.de (for SIP URI)
10343
Webconnect error: Default gateway not configured
It is likely that there is an error in the network settings.
Corrective measures:
• Check the network components (DLAN, WLAN Access Point etc.).
• Ensure that the following ports are not blocked:
– Registrar: ied.sma.de:9523
– Proxy: ied.sma.de:9523
– Stun: stun.sma.de:3478
– Domain: ied.sma.de (for SIP URI)
10344
Webconnect error: DNS server not configured
It is likely that there is an error in the network settings.
Corrective measures:
• Check the network components (DLAN, WLAN Access Point etc.).
• Ensure that the following ports are not blocked:
– Registrar: ied.sma.de:9523
– Proxy: ied.sma.de:9523
– Stun: stun.sma.de:3478
– Domain: ied.sma.de (for SIP URI)
10345
No reply to DNS request
It is likely that there is an error in the network settings.
Corrective measures:
• Check the network components (DLAN, WLAN Access Point etc.).
• Ensure that the following ports are not blocked:
– Registrar: ied.sma.de:9523
– Proxy: ied.sma.de:9523
– Stun: stun.sma.de:3478
– Domain: ied.sma.de (for SIP URI)