2 Safety
SMA Solar Technology AG
Replacement Manual
DC-EMV-STPTL10-RM-xx-10
8
This section contains safety information that must be observed at all times when working.
The product has been designed and tested in accordance with international safety requirements. As
with all electrical or electronical devices, there are residual risks despite careful construction. To
prevent personal injury and property damage and to ensure long-term operation of the product,
read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to electric shock when live components or cables of the
inverter are touched
High voltages are present in the conductive components or cables of the inverter. Touching live
parts and cables of the inverter results in death or lethal injuries due to electric shock.
• Disconnect the inverter from voltage sources and make sure it cannot be reconnected
before working on the device.
• Wear suitable personal protective equipment for all work on the product.
• Do not touch non-insulated parts or cables.
DANGER
Danger to life due to electric shock when live components or DC cables are
touched
When exposed to light, the PV modules generate high DC voltage which is present in the DC
cables. Touching live DC cables results in death or lethal injuries due to electric shock.
• Do not touch non-insulated parts or cables.
• Disconnect the inverter from voltage sources and make sure it cannot be reconnected
before working on the device.
• Do not disconnect the DC connectors under load.
• Wear suitable personal protective equipment for all work on the product.
DANGER
Danger to life due to electric shock when touching live system components in
case of a ground fault
If a ground fault occurs, parts of the system may still be live. Touching live parts and cables
results in death or lethal injuries due to electric shock.
• Disconnect the inverter from voltage sources and make sure it cannot be reconnected
before working on the device.
• Touch the cables of the PV array on the insulation only.
• Do not touch any parts of the substructure or frame of the PV array.
• Do not connect PV strings with ground faults to the inverter.
• Once disconnected from voltage sources, wait five minutes before touching any parts of the
PV system or the inverter.
ENGLISH
Содержание NR-STP-DC-EMV
Страница 68: ...1 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 68 1 5 1 6 X703 1 X703 6 10...
Страница 70: ...2 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 70 SMA Solar Technology AG SMA Solar Technology AG 2 2...
Страница 71: ...2 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 71 DC DC DC DC 5...
Страница 72: ...2 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 72 Electronic Solar Switch ESS DC AC DC 1000 V...
Страница 73: ...2 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 73 5 C v v SMA SMA...
Страница 74: ...3 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 74 SMA Solar Technology AG 3 1 DC 1 ESS 2 11 mm 11 M4x15 1...
Страница 75: ...4 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 75 4 B A 1 A HM DC EMV B PVS 5 DC 1000 V...
Страница 76: ...5 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 76 1 3 2 DC 3 4 ESS ESS ESS ESS ESS 5 LED 6 6 3 7...
Страница 79: ...5 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 79 18 20 20 4 19 2 DC DC DC PE...
Страница 80: ...6 DC SMA Solar Technology AG DC EMV STPTL10 RM xx 10 80 DC PE 20 v v 6 DC 1 5 75...
Страница 81: ...6 DC SMA Solar Technology AG DC EMV STPTL10 RM xx 10 81 2 4 DC 3 DC 3 PVS DC EMV 8 DC EMV 4...
Страница 87: ...9 SMA Solar Technology AG DC EMV STPTL10 RM xx 10 87 SMA Solar Technology AG 2...
Страница 236: ...www SMA Solar com...