Electrical Connection
SMA
Solar Technology AG
Page 22
BATFUSE-TEN082310
Technical Description
5.2 BatFuse B.01 and BatFuse B.03
You can connect two batteries with a capacity up to 800 Ah or one battery with a capacity greater
than 800 Ah to the BatFuse B.03.
The maximum ampacity is dependent upon the Sunny Island (see section 7 "Technical data" (Page
29)).
How to connect the B.01 and B.03 BatFuses:
1.
Remove the lid (see section 6 "Opening and Closing" (Page 28)).
2.
Open the load disconnection unit.
3.
Remove the load disconnection unit from the bracket and store it in a safe place for the
duration of the installation.
4.
Pierce the outer membrane of the required double membrane adapter with a sharp tool.
BatFuse B.01
BatFuse B.03
Maximum number of terminals:
Battery side
1 x M 32 and 2 x M 25
per pin
2 x M 32 and 4 x M 25
per pin
a)
a)
The BatFuse B.03 possesses another M 25 double membrane adapter for the battery voltage tap.
Maximum number of terminals:
Sunny Island side
1 x M 32
per pin
3 x M 32
per pin
Connection possibilities
Battery side
1 battery and 2 charge
controllers
2 batteries and 4 charge
controllers
Battery cable cross section
1 x 70 mm
2 x 70 mm· instead of
1 x 185 mm
Charge controller cable cross
section
10 mm
10 mm