Legal Provisions

SMA Solar Technology AG

Maintenance Manual

SCCP-JP-B1-WA-en-23

2

Legal Provisions

The information contained in these documents is the property of SMA Solar Technology AG. No part of this document
may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic,
mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA Solar Technology AG.
Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not
require prior approval.

SMA Solar Technology AG makes no representations or warranties, express or implied, with respect to this
documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied
warranties of utility, merchantability, or fitness for any particular purpose. All such representations or warranties are
expressly disclaimed. Neither SMA Solar Technology AG nor its distributors or dealers shall be liable for any indirect,
incidental, or consequential damages under any circumstances.

The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may
not apply.

Specifications are subject to change without notice. Every attempt has been made to make this document complete,
accurate and up-to-date. Readers are cautioned, however, that product improvements and field usage experience may
cause SMA Solar Technology AG to make changes to these specifications without advance notice or per contract
provisions. SMA Solar Technology AG shall not be responsible for any damages, including indirect, incidental or
consequential damages, caused by reliance on the material presented, including, but not limited to, omissions,
typographical errors, arithmetical errors or listing errors in the content material.

SMA Warranty

You can download the current warranty conditions from the Internet at www.SMA-Solar.com.

Trademarks

All trademarks are recognized, even if not explicitly identified as such. Missing designations do not mean that a
product or brand is not a registered trademark.

SMA Solar Technology AG

Sonnenallee 1

34266 Niestetal

Germany

Tel. +49 561 9522-0

Fax +49 561 9522-100

www.SMA.de

Email: [email protected]

As of: 7/1/2020

Copyright © 2020 SMA Solar Technology AG. All rights reserved.

Содержание SUNNY CENTRAL 1000CP-JP

Страница 1: ...SCCP JP B1 WA en 23 Version 2 3 ENGLISH Maintenance Manual SUNNY CENTRAL 500CP JP 630CP JP 800CP JP 1000CP JP...

Страница 2: ...under any circumstances The exclusion of implied warranties may not apply in all cases under some statutes and thus the above exclusion may not apply Specifications are subject to change without noti...

Страница 3: ...1 Design 16 3 3 2 2 Explanation of Symbols 16 3 3 3 LEDs of the SC COM 20 3 3 3 1 LEDs on the Enclosure 20 3 3 3 2 LEDs on the Network Port 21 3 3 3 3 LEDs on the Optical Fiber Terminals 22 3 3 4 Use...

Страница 4: ...42 6 2 2 Maintenance Work Every 24 Months 42 6 3 Repair Schedule and Spare Parts 43 6 3 1 Information on Repair Work 43 6 3 2 Demand Based Annual Repairs 43 6 3 3 Repairs every 10 Years 44 6 3 4 Repa...

Страница 5: ...eter Overview 63 7 3 1 Accessing the Parameter Overview 63 7 3 2 Saving Parameter Changes 64 7 4 User Interface 64 7 4 1 Logging Into the User Interface 64 7 4 2 Logging Out of the User Interface 64 8...

Страница 6: ...must only be performed by qualified persons Qualified persons must have the following skills Knowledge of how the product works and is operated Training in how to deal with the dangers and risks assoc...

Страница 7: ...lements to be selected Select Settings Date Button Key Button or key to be selected or pressed Select Enter Placeholder for variable components e g parameter names Parameter WCtlHz Hz 1 6 Designations...

Страница 8: ...oval from the grid operator Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives Any other applicati...

Страница 9: ...arge completely see Section 4 2 page 25 DANGER Danger to life due to electric shock when live components or DC cables are touched When exposed to sunlight the PV modules generate high DC voltage which...

Страница 10: ...ltage to ground Entering the PV field can result in lethal electric shocks Ensure that the insulation resistance of the PV field exceeds the minimum value The minimum value of the insulation resistanc...

Страница 11: ...OTICE Property damage due to dust intrusion and moisture penetration Dust or moisture intrusion can damage the product and impair its functionality Do not open the enclosure during rainfall or when hu...

Страница 12: ...of the art and are very expensive to use special communication interfaces separate wide area networks and more When using the Internet infrastructure the systems connected to the Internet are entering...

Страница 13: ...ure 2 Devices of the inverter Position Device Description A Touch Display Different kinds of inverter data can be viewed on the touch display The touch display is only used to view data The display sc...

Страница 14: ...ey switch Position Designation A Switch position Stop B Switch position Start Switch position Start If the key switch is turned to Start a motor drive switches the DC switchgear on and the inverter sw...

Страница 15: ...unit from ABB Position Designation Explanation A Switch position on The AC disconnection unit is closed B Central switch position The AC disconnection unit was tripped and is open C Switch position of...

Страница 16: ...ers S M or A you can unlock the display again The touch display is divided into three areas 100 DD MM YYYY hh mm ss A B C Figure 6 Design of the touch display Position Designation Explanation A Status...

Страница 17: ...e Inverter data symbol the DC switchgear is closed If you see this symbol between the symbol Inverter data and the symbol AC side the AC contactor is closed Switch on DC or AC side open If you see thi...

Страница 18: ...xcitation type of the displacement power factor Actual reactive power in VAr Actual displacement power factor cos Actual excitation type of the displacement power factor Settings Menu Symbol Designati...

Страница 19: ...ssword entry Information OS version of the operating system App version of the application software SC COM version SC COM software version Ser No inverter serial number Hardware hardware version and s...

Страница 20: ...ge SD1 flashing green Read or write access to system drive SD2 flashing green Read or write access to internal data drive CF flashing green Read or write access to external SD memory card H1 flashing...

Страница 21: ...s used glowing red The internal memory card is full and the oldest saved data is being overwritten flashing red 92 of the storage capacity of the internal memory card is used H5 glowing green An exter...

Страница 22: ...tions If the optical fibers are connected to the splice box of the inverter the status of the connection will be indicated by the LEDs of the SC COM Figure 9 LEDs for the status of the optical fiber c...

Страница 23: ...ice view B Status bar C Logout button D Navigation bar E Content area 3 3 4 2 Tree View and Device View You can call up data of the individual devices of your PV power plant in the tree view or the de...

Страница 24: ...equipment is connected to the grounding conductor sys tem of the product Degree of protection IP54 The product is protected against interior dust deposits and splashing water from all angles Beware of...

Страница 25: ...f burns due to hot components Some components of the product can get very hot during operation Touching these components can cause burns Observe the warnings on all components During operation do not...

Страница 26: ...2 4 Disconnecting the Supply Voltage at the Inverter from Voltage Sources 1 If the supply voltage is only to be disconnected upstream from the circuit breaker switch the circuit breaker of the supply...

Страница 27: ...oltage 4 If the supply voltage has been disconnected downstream from the circuit breaker switch the external circuit breaker of the supply voltage on Tip The external circuit breaker of the supply vol...

Страница 28: ...fuses and disconnection blades into all fuse holders of the inverter Use an LV HRC fuse extractor 2 Screw on the protective covers over the fuses torque 5 Nm 3 Switch on the DC voltage in the DC main...

Страница 29: ...injury due to electric shock Disconnect the external supply voltage WARNING Hearing impairment due to high frequency noises of the product The product generates high frequency noises during operation...

Страница 30: ...Downloading the Event Report The event report keeps a log of various events e g errors and warnings All events can be downloaded in a CSV file Upon delivery the automatic transfer of the events is dea...

Страница 31: ...waiting time The waiting time specifies how long the disturbance will be shown on the touch display and saved as a disturbance Once the waiting time has elapsed the disturbance is no longer shown on...

Страница 32: ...hether the cause of the disturbance has been rectified If the disturbance is no longer pending it is deleted from the memory If the cause of the disturbance still exists after the disturbance has been...

Страница 33: ...When the inverter monitors the utility grid after a grid error the grid monitoring time is complied with Certain errors such as grid errors cause the inverter to shut down In this case the instantane...

Страница 34: ...tand alone grid and has disconnected from the utility grid W W Check power frequency 0801 One line conductor of the utility grid has failed 30 s 30 s Check the grid voltage Make sure the external fuse...

Страница 35: ...on error W W Check the PV array for ground faults 3512 The Remote GFDI has detected a permanent ground fault Q Q Check the PV array for ground faults 3515 A ground fault detected by Soft Grounding has...

Страница 36: ...ervice Line 6121 No response from watchdog 30 s W Contact the SMA Service Line 6122 Ten internal monitoring errors have occurred in succession W 5 min Contact the SMA Service Line 6128 General error 5...

Страница 37: ...act the SMA Service Line 6455 AC voltage is faulty W W Contact the SMA Service Line 6456 Pre charging circuit of DC link is defective W W Contact the SMA Service Line 6457 Capacitor self test has fail...

Страница 38: ...splay only W W Check cabling between touch display and communication unit Contact the SMA Service Line 7601 Internal inverter error 30 s 1 min x Contact the SMA Service Line 7602 Internal communicatio...

Страница 39: ...setpoint is invalid W W Contact the SMA Service Line 8704 External active and reactive power setpoints are invalid W W Contact the SMA Service Line 9008 Doors have been opened during operation 30 s 1...

Страница 40: ...displays errors or warnings relating to the reactive power setpoint Procedure 1 Log into the user interface see Section 7 4 1 page 64 2 Select the instantaneous value Q VArModFailStt Display Cause and...

Страница 41: ...t open the enclosure during rainfall or when humidity exceeds the specified thresholds The humidity thresholds are 15 to 95 Only perform maintenance work when the environment is dry and free of dust O...

Страница 42: ...ntenance operations Spare parts Only original parts or parts recommended by SMA Solar Technology AG are to be used as spare parts when replacing components Spare parts can be identified via the refere...

Страница 43: ...cking the seals Section 6 4 2 6 page 52 Checking the latches door stops and hinges Section 6 4 2 7 page 53 Checking the inverter surface Section 6 4 2 8 page 54 Checking the fuses disconnection blades...

Страница 44: ...placement intervals for order option Q at Night The replacement intervals are halved for order option Q at Night Task Comment Replace interior fan in the inverter cabinet Contact Service Replace the i...

Страница 45: ...UTION Risk of burns due to hot components Some components of the product can get very hot during operation Touching these components can cause burns Observe the warnings on all components During opera...

Страница 46: ...t 6 4 1 3 Checking the Function of the UPS Figure 12 Positon of the UPS Position Designation A Uninterruptible power supply UPS DANGER Danger to life due to electric shock or electric arc if live comp...

Страница 47: ...earlier Contact SMA Solar Technology AG 6 4 2 Maintenance Work in Disconnected State 6 4 2 1 Performing the Visual Inspection DANGER Danger to life due to electric shock or electric arc if live compo...

Страница 48: ...the indicators Type of inverter bridges Number of indicators 1 to 17 with connection terminals at the upper end 17 10 to 17 without connection terminals at the up per end 8 If the temperature exceeds...

Страница 49: ...switching off the product wait until any hot components have cooled down sufficiently Wear suitable personal protective equipment for all work on the product Requirement The inverter must have been op...

Страница 50: ...to life due to electric shock or electric arc if live components are touched Switch off the inverter and wait at least 15 minutes before opening it to allow the capacitors to discharge completely Dis...

Страница 51: ...ion grids if required 5 Pull the front edge of the roof forward and push upward 6 Gently push the roof to the rear In doing so you push the roof out of the guide rails 7 Check whether the air intake i...

Страница 52: ...ctric arc if live components are touched Switch off the inverter and wait at least 15 minutes before opening it to allow the capacitors to discharge completely Disconnect the inverter see Section 4 pa...

Страница 53: ...Checking the Latches Door Stops and Hinges Required maintenance material not included in the scope of delivery A suitable water free and heat resistant lubricant e g WD40 Non greasing antifreeze agen...

Страница 54: ...turer Position RAL color Color Roof RAL 7004 Signal gray Base RAL 7004 Signal gray Enclosure RAL 9016 Traffic white Silencing baffle RAL 7035 Light gray optional DANGER Danger to life due to electric...

Страница 55: ...ion blades are free from hardened grease Clean contact surfaces if they are covered with hardened grease Then apply new grease to the surfaces 5 Insert all fuses and disconnection blades into the fuse...

Страница 56: ...ed by the manufacturer of the surge arrester such as the PM20 by DEHN S HNE GmbH Co KG DANGER Danger to life due to electric shock or electric arc if live components are touched Switch off the inverte...

Страница 57: ...8 62 952315 F730 to F735 62 9983 9299704 6 4 2 12 Checking the Labels Labels on the inverter Inverter labels can be ordered from us as a complete set SMA order number 3J1 050 001 001 Figure 17 Positio...

Страница 58: ...Generators ist im Wechselrichter geerdet 86 1086701017 Der Plus des PV Generators ist im Wechselrichter geerdet I 86 003324 Ungewollte Ausl sung durch ver nderte Einstellungen K 86 0043563 Stromschlag...

Страница 59: ...ng Replace any warning messages and labels which are missing or illegible If necessary you can order labels as a complete set Contact us see Section 9 page 66 6 5 Repair Work 6 5 1 Reading off the Rep...

Страница 60: ...cted to the inverter via the grounding conductor If the roof is not disassembled correctly the grounding conductors may be pulled out Take care not to damage the grounding conductors during disassembl...

Страница 61: ...rc if live components are touched Switch off the inverter and wait at least 15 minutes before opening it to allow the capacitors to discharge completely Disconnect the inverter see Section 4 page 25 D...

Страница 62: ...rids 1 Release the screws of the right hand ventilation grid head size T40 2 Pull the lower side of the right hand ventilation grid forwards to remove it 3 Release the screws of the left hand ventilat...

Страница 63: ...g the Password via the Touch Display Installer access The Installer access level is activated by entering the installer password The access level is reset after 15 minutes Procedure 1 Select 2 Select...

Страница 64: ...s for the user groups If your user password is the same as your installer password you will automatically be logged in as an installer Requirement JavaScript must be enabled in your web browser e g In...

Страница 65: ...tive covers 5 Nm 8 2 Type Label The type label clearly identifies the product One type label is present in the inverter The type label is located in the right hand top corner inside the interface cabi...

Страница 66: ...ur products please contact the SMA Service Line The following data is required in order to provide you with the necessary assistance Device type Firmware version Event message Type of communication Ty...

Страница 67: ......

Страница 68: ...www SMA Solar com...

Отзывы: