background image

ENGLISH 

OPERATING MANUAL FOR 
OUTDOOR LUMINAIRE 
231455 / 231457 / 231815 / 231817 

  

Read this short manual carefully and keep it accessible for further 
reference! 

  

 

SAFETY MESSAGES

 

  

Disregard of the safety messages may lead to danger of life, burning or 
fire!

 

  Installation, mounting or works on the electrical connection may only be 

carried out by an approved electrician. 

  Type Y attachement: If the external flexible cable or cord of this luminaire is 

damaged, it shall be exclusively replaced by the manufacturer or a 
qualified electrician. 

  The cable of the product may not be placed underground. 

  The product may not be modified or converted. 

  Do not hang or fasten anything on the product, especially no decoration. 

  Do not cover the product - provide free air circulation. 

  The foot or the base of the luminaire must be kept free and may not be 

covered with dirt, leaves, etc. 

  Openings providing aeration or drainage may not be covered. 

  The luminaire may only be operated with a complete and intact protection 

glass. 

  In case of a malfunction you may NOT touch the product or operate it 

further. Disconnect the product from the power supply by an external 
switch or by the fuse. 
A malfunction exists when: 

  visible damages appear. 

  the product does not work properly (e.g. flickering). 

  smoke, steam or crackling sounds appear. 

  smell of burning is recognisable. 

  an overheating is recognisable (e.g. by discolouration of adjacent 

surfaces). 

Operate the product only after maintenance and examination by an 
approved electrician!

 

  This product is not intended to be used by children. Ensure that children do 

not suffer any harm e.g. by burns from hot surfaces or by electrical shock. 

Additional safety messages are indicated by this symbol: 

 . 

  

USE AS DIRECTED 

  

This product serves exclusively lighting purposes and may: 

  only be used with a voltage of 220-240V ~50/60Hz. 

  only be installed according to safety class I (one). 

  only be operated when firmly mounted on a stable, even and tilt-fixed 

surface. 

  only be operated on normally or not flammable surfaces. 

  not be exposed to strong mechanical loads or to strong contamination. 

 

 
 
 
 
 
 
 
 

MAINTENANCE AND CARE

 

  

Light source

 

  The light source of this luminaire may only be replaced by the manufacturer, 

an authorized service technician or a comparable qualified person. 

  

Care 

  The following enviromental influences may have unwanted effects on the 

surface of the product: 

  acid rain and sour soil, high salt content in the air 

  cleaning agents, fertilizer especially in flowerbeds 

  thawing salt, other chemical substances (e.g. herbicides)  

Protect the product by adequate means to avoid unwanted changes of the 
surface. 

 

Disconnect the product from the power supply and let it cool down, before 

you clean the product. 

  Clean the product on a regular basis using a slightly moistened, soft and fluff-

free cloth. Please also note additional supplied notes on maintanance and 
care. 

  

STORAGE AND DISPOSAL

 

  

Storage 

  The product must be stored in a dry and clean environment. Do not strain 

the product mechanically during storage. 

 After a damp or soiling storage the product may only be installed after 

checking its condition by an approved electrician. 

Disposal 

(European Union) 

 

  Do not dispose the product with the regular household waste! Products 

marked with this sign must be disposed according to the directive (WEEE, 
2012/19) on electrical and electronic devices at local collection points for such 
devices! 

  

INSTALLATION 

(only by an approved electrician)

 

  

 

Switch off the mains or respectively the connection lead before doing any 

works! 

 

Use only parts, which are supplied with the product or are described as 

accessories! 

 

Inspect the product for loose parts inside the housing. When there are loose 

parts inside the housing and these are not explicitly described the product may 
not be installed or operated. 

 

 

Use the supplied fastening material only when it is suited for the installation 

background. If this is not the case use only fastening material suiting the 
installation background.

 

  

Unpacking 

  Carefully take the product out of the packaging removing any transport 

safeguards. 

  Before disposal of the packaging material make sure that all components of 

the product are removed. 

 

 
 
 
 
 
 
 

Installation place 

  The product is solely suited for installation on the floor. 

  LED react sensitive on high temperatures! Before installation pay attention 

to the expected temperature at the place of operation. This may not exceed 
the allowed ambient temperature (ta=40°C) of the product. 

  The foot or the base of the luminaire must be kept free and may not be 

covered with dirt, leaves, etc. 

 The product may only be utilized according to IP44. 

IP44: Protection against foreign objects > Ø 1,0mm - Protection against 
splashing water from all directions. 

 Choose a place where the installation is not a danger (e.g. stumbling, 

knocking). 

 Prepare the power supply lead according to valid rules for outdoor 

installations. 

 Do not seal the product yourself, using additional silicon or another 

sealant. 

  

Installation steps 

(read completely before installation)

 

  There are different types of mounting: 

  Screw-set (art. no.: 228753): Screws, plug and nut for direct mounting 

of the luminaire. 

  Concrete anchor (Consignment): For casting into liquid concrete, 

including threads and nuts. 

 Electrical 

Connection 

  The product must be able to be separated by an all pole separation 

from the current supply. 

  Use a suitable outdoor connection box (e.g. art.-no. 228730), to 

connect the luminaire. 

  Connect the black or brown wire (live conductor), the blue wire 

(neutral conductor) and the green-yellow wire (protective conductor) 
of the mains supply with the corresponding wires of the product. 

  Secure the cable screwing using a suitable tool. 

  Fasten the luminaire on the mounting surface. 

  Note the proper fit for the gasket. 

 Check if the product functions properly and is securely fixed! 

  

art.-no. 231455 / 231457 / 231815 / 231817 © 06.06.2018 SLV GmbH, 
Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, 
Tel. +49 (0)2451 4833-0 
Technical Details are subject to change. 