SloanLED PrismBEAM 24V
Installation Guide for 701972-(C)WP(D,S)(X)2
PAGE 1 OF 4
1. Tools required:
1. Measuring tape
2. Wire strippers
3. Gloves
4. Drill
5. Screwdriver
WARNING:
Use SloanLED Prism BEAM 24V
with 100 W 24 VDC Power Supply only.
WARNING: Risk of electrical shock. New installation and LED Retrofit Kit installation requires knowledge of sign electrical systems.
If not qualified, do not attempt installation. Contact a qualified electrician. Follow all NEC and local codes. SloanLED PrismBEAM 24V
is not suitable for submersion or direct exposure to water for extended periods of time.
For New Installation, proceed with Step 1 below. For Retrofit Installations, begin with Retrofit Instructions on page 3.
New Installation
2.
Components list:
• SloanLED PrismBEAM 24V assemblies:
Double-sided assemblies:
model numbers 701972-(C)WPD(X)2
Single-sided assemblies:
model numbers 701972-(C)WPS(X)2
• Power supplies: SloanLED 24 V
Class 2 output power supply (refer to
"100 W 24 VDC Power Supply Capacity
Chart" for appropriate model numbers)
• UL approved 18 AWG (1 mm
2
) or larger
diameter supply wire
• UL approved wire connectors appropriate
for wire gauge used
• Optional: Electrical grade silicone,
4" (101.6 mm) nylon zip ties, conduit and
conduit connectors (water tight if necessary)
4.
Determine lengths and quantities of
SloanLED PrismBEAM 24V
(see Power Supply capacity table on
page 4). Determine quantity of brackets
(P/N 402297): Two (2) per
SloanLED PrismBEAM 24V assembly.
NOTE:
Lamps must be mounted in an
enclosed sign. This product is not suitable
for immersion or direct exposure to water
for extended periods of time.
Brackets
Lampholders
Lampholder
Bracket
Optional:
Bracket designed to
mount over existing lampholders
to provide greater stability, at the
installer's discretion.
3. Install fluorescent lampholders or SloanLED PrismBEAM 24V
Brackets (P/N 402297) 12" (305 mm) center-to-center along
returns of cabinet (see Layout Guidelines on page 2).
5.
Optional field cut:
If lamp needs to be shortened
to a different length, measure
and cut on end indicated by
label, to new length according
to table (includes end caps).
Re-attach end cap and cap
all cut wires. If LED module(s)
interfere with cut, remove
module(s) and cap cut wires.
Nominal
Actual
Nominal
Actual
18" (0.46 m)
15.72" (0.40 m)
64" (1.63 m)
61.72" (1.57 m)
24" (0.61 m)
21.72" (0.55 m)
72" (1.83 m)
69.72" (1.77 m)
30" (0.76 m)
27.72" (0.70 m)
84" (2.13 m)
81.72" (2.08 m)
36" (0.91 m)
33.72" (0.86 m)
96" (2.44 m)
93.72" (2.38 m)
42" (1.07 m)
39.72" (1.01 m)
108" (2.74 m)
105.72" (2.69 m)
48" (1.22 m)
45.72" (1.16 m)
117" (2.97 m)
114.72" (2.91 m)
60" (1.52 m)
57.72" (1.47 m)
120" (3.05 m)
117.72" (2.99 m)
Lamp Lengths
TIP:
End cap adds exactly 0.50" (12.7 mm) to length of extrusion.