background image

SloanLED PrismBEAM 24V

Installation Guide for 701972-(C)WP(D,S)(X)2

PAGE 2 OF 4

6.  Insert SloanLED PrismBEAM 24V into lampholders 

or SloanLED PrismBEAM 24V Brackets. 

Support 

center for lengths 96" and above. 

Tip: For easy wire 

connections, install all lamps in same direction with wire 

leads on same end.

7.  Connections: Product may be connected in series 

or parallel. End wires should be capped and not 

tied back to power supply. (NOTE: All connections 

must be RED STRIPE-TO-RED STRIPE [+] and 

WHITE-TO-WHITE [-]).

Primary Wires

Secondary Wires

Mounting Tabs

8. 

Mount power supply:

 Identify primary 

wires, secondary wires, and location of 

mounting tabs.

9.  Units may be mounted in any orientation 

using mounting tabs.

10. 

Connect primary:

 

CAUTION!

 Have a 

licensed electrician connect primary.

11. 

Connect to power supply:

 Using UL Listed 

electrical connectors, connect to power supply.

 

Do not connect power to lamp sockets.

NOTE:

 Power supply to 

luminaire connections must be 

RED STRIPE-TO-RED [+] and 

WHITE-TO-BLACK [-]).

Layout Guidelines

Mount SloanLED PrismBEAM 24V in center of returns in double-sided cabinets. For best results, lamps should be ≥8" (≥203 mm) from face of sign. It's 

recommended to test LED density in a sample cabinet to evaluate brightness, uniformity, and color. If you have questions or require assistance in testing, 

please contact your SloanLED Customer Service Representative.

Содержание PrismBEAM 24V

Страница 1: ...nduit connectors water tight if necessary 4 Determine lengths and quantities of SloanLED PrismBEAM 24V see Power Supply capacity table on page 4 Determine quantity of brackets P N 402297 Two 2 per SloanLED PrismBEAM 24V assembly NOTE Lamps must be mounted in an enclosed sign This product is not suitable for immersion or direct exposure to water for extended periods of time Brackets Lampholders Lam...

Страница 2: ...ry wires secondary wires and location of mounting tabs 9 Units may be mounted in any orientation using mounting tabs 10 Connect primary CAUTION Have a licensed electrician connect primary 11 Connect to power supply Using UL Listed electrical connectors connect to power supply Do not connect power to lamp sockets NOTE Power supply to luminaire connections must be RED STRIPE TO RED and WHITE TO BLAC...

Страница 3: ...or location sign repair and seal any unused openings in the electrical enclosure Openings greater than 0 5 12 7 mm diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openings may be sealed with non hardening caulk 5 Clean inside of sign using non oil based cleaner Follow all manufacturer s instructions and ensure inside of sign is dry before pro...

Страница 4: ...t will not cause entire box cabinet to go out If one lamp does not light but all others do replace this lamp with a new one If longer lead wire from power supply to LED product is needed an extension can be used Extension should be kept as short as possible i e under 15 ft use 18 AWG UL Listed PLTC 4 6 m for 1 mm PLTC or under 50 ft use 14 AWG UL Listed PLTC 15 2 m for 2 5 mm PLTC Extension of Pow...

Отзывы: