Troubleshooting

Entire box/cabinet or product 

does not light after complete 

 

installation.

Check connection from power supply lead to first lamp. Make sure polarity of connections made at power supply lead and any jumper 

wire is correct. Power supply outputs should be connected RED-TO-RED (+) and BLACK-TO-WHITE (-).

Still does not light.

Check output voltage of power supply using a voltmeter. Output voltage should be DC 24.0 V ± 0.5 V. If there is no output voltage, 

have a licensed electrician check input voltage. Make sure power supply is connected correctly and getting primary power. If power 

supply is connected properly and getting primary power and there is still no output voltage, try a different power supply.

Still does not light.

If power supply is getting primary power and lamps don’t light, there may be a short in secondary wiring.

 

Check all connections and cap all loose wires.

The beginning of a lamp lights, 

but entire lamp does not light or 

lights intermittently.

Primary cause of a portion of a lamp not lighting or lighting intermittently is a bad connection or reverse polarity connection between 

lamps that light and lamps that don’t light. Check this connection.

One lamp does not light, but all 

others in cabinet light.

SloanLED PrismBEAM 24V

 

is designed so if one lamp fails, it will not cause entire box/cabinet to go out. If one lamp does not light, but 

all others do, replace this lamp with a new one.

If longer lead wire from power supply to LED product is needed, an extension can be used. Extension should be kept as short as possible, 

i.e., under 15 ft use 18 AWG UL Listed PLTC (4.6 m for 1 mm² PLTC) or under 50 ft use 14 AWG UL Listed PLTC (15.2 m for 2.5 mm² PLTC).

Extension of Power Supply Leads

100 W 24 VDC Power Supply Capacity Table for SloanLED PrismBEAM 24V

 

(or any combination not to exceed max. output of power supply)

Input

Output

Maximum Lamps per Power Supply (Single-sided / Double-sided)

Part Number

Retrofit 

Certified

Nominal Input

 

Voltage

Input

 

Current

Power

 

Output

Output

 

Current

18 in 

(0.46 m)

24 in

 

(0.61 m)

30 in

 

(0.76 m)

36 in

 

(0.91 m)

42 in

 

(1.07 m)

48 in

 

(1.22 m)

60 in

 

(1.52 m)

64 in

 

(1.63 m)

72 in

 

(1.83 m)

84 in

 

(2.13 m)

96 in

 

(2.44 m)

108 in

 

(2.74 m)

117 in

 

(2.97 m)

120 in

 

(3.05 m)

701895-24C*

100-240 V

2.0 A 100 W 4.2 A

28 / 14

19 / 9

19 / 9

14 / 7

11 / 5

9 / 4

8 / 4

7 / 3

6 / 3

5 / 2

4 / 2

4 / 2

4 / 2

4 / 2

701895-24C1*

100-277 V

1.4 A

96 W

4.0 A

28 / 14

19 / 9

19 / 9

14 / 7

11 / 5

9 / 4

8 / 4

7 / 3

6 / 3

5 / 2

4 / 2

4 / 2

4 / 2

4 / 2

701895-24S1

100-277 V

1.4 A

96 W

4.0 A

28 / 14

19 / 9

19 / 9

14 / 7

11 / 5

9 / 4

8 / 4

7 / 3

6 / 3

5 / 2

4 / 2

4 / 2

4 / 2

4 / 2

Capacities based on 90W

 

of power supply output 

Power used per 

lamp in Watts:

3.1 /

 

6.2 W

4.7 /

 

9.4 W

4.7 /

 

9.4 W

6.2 /

 

12.5 W

7.8 /

 

15.6 W

9.4 /

 

18.7 W

10.9 /

 

21.8 W

12.5 /

 

25.0 W

14.0 /

 

28.1 W

15.6 /

 

31.2 W

18.7 /

 

37.4 W

20.3 /

 

40.6 W

21.8 /

 

43.7 W

21.8 /

 

43.7 W

NOTE: 

Each 24 V circuit must be limited to 4.2 A (100 W) or less. For North American installations, a power supply that meets NEC Class 2 specifications is required.

Power Supply Capacity calculations for field cut lengths use 1.63 watts per module.

* Wet location power supply: Refer to install guide for configurations.

WARNING:

 Use SloanLED PrismBEAM 24V with 100 W 24 VDC Power Supply only.

Содержание PrismBEAM 24V

Страница 1: ...nduit connectors water tight if necessary 4 Determine lengths and quantities of SloanLED PrismBEAM 24V see Power Supply capacity table on page 4 Determine quantity of brackets P N 402297 Two 2 per SloanLED PrismBEAM 24V assembly NOTE Lamps must be mounted in an enclosed sign This product is not suitable for immersion or direct exposure to water for extended periods of time Brackets Lampholders Lam...

Страница 2: ...ry wires secondary wires and location of mounting tabs 9 Units may be mounted in any orientation using mounting tabs 10 Connect primary CAUTION Have a licensed electrician connect primary 11 Connect to power supply Using UL Listed electrical connectors connect to power supply Do not connect power to lamp sockets NOTE Power supply to luminaire connections must be RED STRIPE TO RED and WHITE TO BLAC...

Страница 3: ...or location sign repair and seal any unused openings in the electrical enclosure Openings greater than 0 5 12 7 mm diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openings may be sealed with non hardening caulk 5 Clean inside of sign using non oil based cleaner Follow all manufacturer s instructions and ensure inside of sign is dry before pro...

Страница 4: ...t will not cause entire box cabinet to go out If one lamp does not light but all others do replace this lamp with a new one If longer lead wire from power supply to LED product is needed an extension can be used Extension should be kept as short as possible i e under 15 ft use 18 AWG UL Listed PLTC 4 6 m for 1 mm PLTC or under 50 ft use 14 AWG UL Listed PLTC 15 2 m for 2 5 mm PLTC Extension of Pow...

Отзывы: