1 - INSTALL FAUCET
2 - SLIDE GASKET OVER FLEX HOSE(S) AND SECURE
3 - INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP. OPEN SUPPLY STOPS
A
Remove Nut, Faucet
Retainer and Gasket.
DO NOT
remove the O-ring
from base of Faucet.
DO NOT
remove
Sensor label unitl Step
4.
FAUCET
CENTER HOLE IN
DECK OR LAVATORY
GASKET
FAUCET RETAINER
NUT
O-RING —
DO NOT REMOVE
O-RING
Install Faucet with O-ring into
the center hole in deck or
lavatory —
1-3/16” (30 mm)
min. hole required.
Note:
If installing the Faucet
on a three (3) hole sink, a
Trim Plate should be installed
at this time.
B
13 mm
NUT
FAUCET
FLEX HOSE
O-RING
A
Install Strainer and Flex Hose
onto Supply Stop.
B
Tighten the Flex Hose
(with Strainer in place)
securely to the Supply.
IMPORTANT: Flush dirt, debris, and sediment from supply
line(s) before Connecting Flex Hoses.
SUPPLY
LINE/ STOP
STRAINER
FLEX HOSE
ADAPTER
SENSOR LABEL
C
Open Supply Stop(s).
B
Remove Label from
Sensor Window.
2
A
For EAF-200 Models,
Plug Adapter into
receptacle.
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
DAISY CHAIN
ELECTRICAL
CABLE
DAISY CHAIN
ELECTRICAL
CABLE
DAISY CHAIN
ELECTRICAL
CABLE
TO
ADDITIONAL
FAUCETS
(6 MAX.)
6 VDC PLUG-
IN ADAPTER
GASKET
FAUCET
RETAINER
MODELS POWERED BY
PLUG-IN ADAPTER ONLY
DO NOT pull or crimp AC
Power Line.
NOTE:
EAF-225 can only connect one (1) faucet per one (1) adapter.
4 - EAF-200 MODELS: PLUG ADAPTER INTO RECEPTACLE.
ALL MODELS - REMOVE LABEL FROM SENSOR.