background image

1 - INSTALL FAUCET

2 - SLIDE GASKET OVER FLEX HOSE(S) AND SECURE

3 - INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP. OPEN SUPPLY STOPS

A

Remove Nut, Faucet 

Retainer and Gasket.

DO NOT

 remove the O-ring 

from base of Faucet.

DO NOT 

remove 

Sensor label unitl Step 

4.

FAUCET

CENTER HOLE IN 

DECK OR LAVATORY

GASKET

FAUCET RETAINER

NUT

O-RING — 

DO NOT REMOVE

O-RING

Install Faucet with O-ring into 

the center hole in deck or 

lavatory — 

1-3/16” (30 mm) 

min. hole required.

Note:

 If installing the Faucet 

on a three (3) hole sink, a 

Trim Plate should be installed 

at this time.

B

13 mm

NUT

FAUCET

FLEX HOSE

O-RING

A

Install Strainer and Flex Hose 

onto Supply Stop.

B

Tighten the Flex Hose 

(with Strainer in place) 

securely to the Supply.

IMPORTANT: Flush dirt, debris, and sediment from supply 

line(s) before Connecting Flex Hoses.

SUPPLY 

LINE/ STOP

STRAINER

FLEX HOSE

ADAPTER

SENSOR LABEL

C

Open Supply Stop(s).

B

Remove Label from 

Sensor Window.

2

A

For EAF-200 Models, 

Plug Adapter into 

receptacle. 

Electrical Connection for up to Six (6) Faucets Using One (1) Adapter

DAISY CHAIN 

ELECTRICAL 

CABLE

DAISY CHAIN 

ELECTRICAL 

CABLE

DAISY CHAIN 

ELECTRICAL 

CABLE

TO 

ADDITIONAL 

FAUCETS  

(6 MAX.)

6 VDC PLUG-

IN ADAPTER

GASKET

FAUCET 

RETAINER

MODELS POWERED BY 

PLUG-IN ADAPTER ONLY

DO NOT pull or crimp AC 

Power Line.

NOTE:

  EAF-225 can only connect one (1) faucet per one (1) adapter.

4 - EAF-200 MODELS: PLUG ADAPTER INTO RECEPTACLE. 

     ALL MODELS - REMOVE LABEL FROM SENSOR.

Содержание Solis EAF-275 Series

Страница 1: ...330 mm LONG FLEX HOSE MIXING LEVER Can Be Set and Removed TEMPERED SUPPLY SPOUT O RING 1 3 16 30 mm MIN DIA HOLE REQUIRED GASKET RETAINER NUT 13 330 mm LONG FLEX HOSE 1 1 2 38 mm MAX DECK THICKNESS I...

Страница 2: ...r and Flex Hose onto Supply Stop B Tighten the Flex Hose with Strainer in place securely to the Supply IMPORTANT Flush dirt debris and sediment from supply line s before Connecting Flex Hoses SUPPLY L...

Страница 3: ...y Stop s NOTE Replace Battery when red LED indicator flashes each time faucet is in use or when faucet stops functioning 3 D Insert a new 6 Volt Type CR P2 Lithium Battery The red LED will flash for o...

Страница 4: ...emove cover BLUE Cold End Position RED HOT End Position Tempered Position B Press button for approximately 5 seconds C When illuminant glows PURPLE release E Press button once F Replace top cover 1 D...

Страница 5: ...ess button twice and release C Illuminant flashes red D Adjust mixing lever for position RED hot and press button once E Illuminant flashes F Adjust mixing lever for position temperate and press butto...

Страница 6: ...A B C D E F G DISCLAIMER Updated electronics have visible red and green LED Original electronics have only red LED and range setting is reversed 1 longest 8 shortest FACTORY SETTING IS APPROPRIATE FOR...

Страница 7: ...range the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet Water will flow until the hands are removed or until the faucet reach...

Страница 8: ...uncontrolled manner Cause Faucet is defective Solution Contact the Sloan Technical Support see below 3 Problem Faucet does not deliver any water when Sensor is activated Indicator Solenoid valve produ...

Отзывы: