background image

DO NOT USE

 abrasive or chemical cleaners (including chlorine bleach) to clean Faucets that may dull the luster and 

attack the chrome or special decorative finishes. Use 

ONLY

 mild soap and water, then wipe dry with clean cloth or 

towel.
While cleaning the bathroom tile, protect the Faucet from any splattering of cleaner. Acids and 

cleaning fluids will discolor or remove chrome plating.

As the user’s hands enter the beam’s effective range, the beam is reflected back into the sensor 

receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until 

the hands are removed or until the faucet reaches its automatic time out limit setting.

OPERATION

CARE AND CLEANING

12/24 LINE PURGE FEATURE

HOT LIMIT STOP ADJUSTMENT

7

 ... 1 x

... 3 x

... 2 x

1x  24 sec 

+  ...

1x

2x

3x

4x

5x

7x

8x

6x = factory setting

1 x (   1x, 2x,...,8x)

4x

2x + 

1x 5 sec

A

A

B

C

 ... 1 x

... 3 x

... 2 x

1x  24 sec 

+  ...

1x

2x

3x

4x

5x

7x

8x

6x = factory setting

1 x (   1x, 2x,...,8x)

4x

2x + 

1x 5 sec

Activate 12HR

Activate 24HR

B

C

 ... 1 x

... 3 x

... 2 x

1x  24 sec 

+  ...

1x

2x

3x

4x

5x

7x

8x

6x = factory setting

1 x (   1x, 2x,...,8x)

4x

2x + 

1x 5 sec

Deactivate

D

This feature will operate the faucet every 12 or 24 hours since last 
use, if not used to prevent stagnant water conditions.

Default purge duration is two minutes.

Consult factory regarding other timing options.

Содержание Solis EAF-275 Series

Страница 1: ...330 mm LONG FLEX HOSE MIXING LEVER Can Be Set and Removed TEMPERED SUPPLY SPOUT O RING 1 3 16 30 mm MIN DIA HOLE REQUIRED GASKET RETAINER NUT 13 330 mm LONG FLEX HOSE 1 1 2 38 mm MAX DECK THICKNESS I...

Страница 2: ...r and Flex Hose onto Supply Stop B Tighten the Flex Hose with Strainer in place securely to the Supply IMPORTANT Flush dirt debris and sediment from supply line s before Connecting Flex Hoses SUPPLY L...

Страница 3: ...y Stop s NOTE Replace Battery when red LED indicator flashes each time faucet is in use or when faucet stops functioning 3 D Insert a new 6 Volt Type CR P2 Lithium Battery The red LED will flash for o...

Страница 4: ...emove cover BLUE Cold End Position RED HOT End Position Tempered Position B Press button for approximately 5 seconds C When illuminant glows PURPLE release E Press button once F Replace top cover 1 D...

Страница 5: ...ess button twice and release C Illuminant flashes red D Adjust mixing lever for position RED hot and press button once E Illuminant flashes F Adjust mixing lever for position temperate and press butto...

Страница 6: ...A B C D E F G DISCLAIMER Updated electronics have visible red and green LED Original electronics have only red LED and range setting is reversed 1 longest 8 shortest FACTORY SETTING IS APPROPRIATE FOR...

Страница 7: ...range the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet Water will flow until the hands are removed or until the faucet reach...

Страница 8: ...uncontrolled manner Cause Faucet is defective Solution Contact the Sloan Technical Support see below 3 Problem Faucet does not deliver any water when Sensor is activated Indicator Solenoid valve produ...

Отзывы: