8
Place your hands under the dispenser to
activate the sensor. For multiple soap
applications, remove hands and place
again under the unit to re-activate.
Sensor Model features:
Sensor:
Recognizes hands so there is
no need to touch the unit.
Safety switch:
Open the cover, set the
power to OFF and the unit will no
longer dispense.
Pilot lamp:
When the sensor
recognizes a user’s hands, the red LED
will light. When the batteries lose
power, the red LED light flashes.
Key:
Use the special key to open/close
the dispenser cover.
Precautions
•
Before using the dispenser,
thoroughly read the “Precautions”
attached to the liquid products.
•
Immediately clean any spill on the
floor to help avoid falling, injuries or
other hazards.
STEP 1.
Operating instructions for manual
models (Fig. 17)
Press the lever to dispense the soap or
sanitizer onto hands.
NOTE: After the pouch is installed, liquid may
not dispense immediately. To prime the unit,
pump the lever until it dispenses. Do not
pump violently.
OPERATION
Dispensing
Long
Short
Medium
Mode
Position of
Left
Middle
Right
Mode Switch
Indicator
Blink 1X Blink 2X Blink 3X
Lamp
STEP 2.
Mode setting for Sensor Models
(Fig. 18)
Dispensing times can be adjusted to any
of three modes.
1. Open the cover.
2. Pull out mode switch cover.
3. Using a screwdriver or the tip of a pen,
switch the mode switch to the desired
setting. The indicator lamp will blink
according to the mode selected.
Fig. 17