background image

3

A

Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼"
(32 mm) shorter than this measurement. Chamfer O.D. and I.D. of
water supply pipe.

WATER SUPPLY PIPE

FINISHED WALL

1-1/4”

(32 mm)

C/L OF

FIXTURE

SPUD

SWEAT
SOLDER
ADAPTER

B

Slide Threaded Adapter fully onto pipe.

C

Sweat solder the Adapter to pipe.

With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbing

grease on any valve component or coupling!

!!! IMPORTANT !!!

Protect the chrome or special finish of Sloan Flushometers — DO NOT USE

toothed tools to install or service these valves. Use a Sloan A-50 

Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench to

secure all couplings. Also see “Care and Cleaning” section of this manual.

!!! IMPORTANT !!!

This product contains mechanical and/or electrical components that are subject

to normal wear. These components should be checked on a regular basis and

replaced as needed to maintain the valve’s performance.

!!! IMPORTANT !!!

Please take the time to read this manual to ensure proper product installation and

longevity. Also, please visit our website to download our most recent

documentation for this product.

If you have questions about how to install your Flushometer, consult your local

Sloan Representative or call Sloan Installation Engineering Department at:

1-888-SLOAN-14 (1-888-756-2614)

VACUUM

BREAKER

TUBE

SPUD COUPLING

NYLON SLIP

GASKET

RUBBER
GASKET

SPUD FLANGE

E

Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over Vacuum Breaker Tube.

F

Insert Tube into Fixture Spud.

G

Hand tighten Spud Coupling onto Fixture Spud.

Thread Control Stop onto
pipe. Tighten with a
wrench making sure outlet
is positioned as required.

H

-7

00

 S

ER

IES

 STOP

BAK-CHEK

®

CONTROL STOP

COVER TUBE †

IRON PIPE NIPPLE OR
COPPER PIPE WITH
SWEAT SOLDER ADAPTER

SETSCREW †

SUPPLY
FLANGE

X

WATER

SUPPLY PIPE

SWEAT SOLDER
ADAPTER

COVER TUBE

WALL
FLANGE

SETSCREW

A

Measure from finished
wall to first thread of
Adapter or threaded
supply pipe (dimension
“X”). Cut Cover Tube to
this length.

B

Slide Cover Tube over
pipe. Slide Wall Flange
over Cover Tube until
against wall.

C

VACUUM

BREAKER

TUBE

SPUD COUPLING

NYLON SLIP

GASKET

RUBBER
GASKET

SPUD FLANGE

SPUD COUPLING

NYLON
SLIP
GASKET

RUBBER
GASKET

SPUD FLANGE

MODELS 

110/111, 113,

115, 116 & 117

MODELS 
120 & 122

MODEL 180

MODEL 186

Tighten Setscrew with a 1/16” hex wrench. DO NOT install Vandal
Resistant Plug at this time.

D

ELBOW FLUSH

CONNECTION

Never open Control Stop to where the flow from the valve

exceeds the flow capability of the fixture. In the event of a valve failure, the

fixture must be able to accommodate a continuous flow from the valve.

!!! IMPORTANT !!!

VACUUM

BREAKER

PLUG

† COVER TUBE AND CAST SUPPLY FLANGE

WITH SETSCREW ARE AVAILABLE IN 
“YBYC” SWEAT SOLDER KIT.

1 - INSTALL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES

NOT HAVE A MALE THREAD)

2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO 

SUPPLY PIPE AND INSTALL VACUUM BREAKER FLUSH CONNECTION

Отзывы: