3
A
Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼"
(32 mm) shorter than this measurement. Chamfer O.D. and I.D. of
water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter fully onto pipe.
C
Sweat solder the Adapter to pipe.
With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbing
grease on any valve component or coupling!
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO NOT USE
toothed tools to install or service these valves. Use a Sloan A-50
Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench to
secure all couplings. Also see “Care and Cleaning” section of this manual.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components that are subject
to normal wear. These components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
!!! IMPORTANT !!!
Please take the time to read this manual to ensure proper product installation and
longevity. Also, please visit our website to download our most recent
documentation for this product.
If you have questions about how to install your Flushometer, consult your local
Sloan Representative or call Sloan Installation Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614)
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
E
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over Vacuum Breaker Tube.
F
Insert Tube into Fixture Spud.
G
Hand tighten Spud Coupling onto Fixture Spud.
Thread Control Stop onto
pipe. Tighten with a
wrench making sure outlet
is positioned as required.
H
-7
00
S
ER
IES
STOP
BAK-CHEK
®
CONTROL STOP
COVER TUBE †
IRON PIPE NIPPLE OR
COPPER PIPE WITH
SWEAT SOLDER ADAPTER
SETSCREW †
SUPPLY
FLANGE
X
WATER
SUPPLY PIPE
SWEAT SOLDER
ADAPTER
COVER TUBE
WALL
FLANGE
SETSCREW
A
Measure from finished
wall to first thread of
Adapter or threaded
supply pipe (dimension
“X”). Cut Cover Tube to
this length.
B
Slide Cover Tube over
pipe. Slide Wall Flange
over Cover Tube until
against wall.
C
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
SPUD COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
MODELS
110/111, 113,
115, 116 & 117
MODELS
120 & 122
MODEL 180
MODEL 186
Tighten Setscrew with a 1/16” hex wrench. DO NOT install Vandal
Resistant Plug at this time.
D
ELBOW FLUSH
CONNECTION
Never open Control Stop to where the flow from the valve
exceeds the flow capability of the fixture. In the event of a valve failure, the
fixture must be able to accommodate a continuous flow from the valve.
!!! IMPORTANT !!!
VACUUM
BREAKER
PLUG
† COVER TUBE AND CAST SUPPLY FLANGE
WITH SETSCREW ARE AVAILABLE IN
“YBYC” SWEAT SOLDER KIT.
1 - INSTALL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES
NOT HAVE A MALE THREAD)
2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO
SUPPLY PIPE AND INSTALL VACUUM BREAKER FLUSH CONNECTION