background image

4

C

Align Flushometer Body. Using a wrench, securely tighten
couplings in the order given: (1) Tailpiece Coupling, (2) Vacuum
Breaker Coupling and (3) Spud Coupling. 

B

Align Flushometer directly above the Vacuum Breaker Flush
Connection by sliding the Flushometer Body IN or OUT as needed.
Tighten Vacuum Breaker Coupling by hand.

A

Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece
into Control Stop. Tighten Tailpiece Coupling by hand.

Maximum adjustment of the Sloan Adjustable Tailpiece is 1/2" 

(13 mm) IN or OUT from the standard 4-3/4" (121 mm) (centerline of

Flushometer to centerline of Control Stop).

If roughing-in measurement exceeds 5-1/4” (133 mm), consult

factory for longer tailpiece.

NOTE

TAILPIECE

COUPLING

CONTROL

STOP

1

FLUSHOMETER

BODY

VACUUM

BREAKER

COUPLING

2

ADJUSTABLE

TAILPIECE

O-RING

G-44

FRICTION

RING

SPUD

COUPLING

3

C/L

FIXTURE

C/L

SUPPLY

VACUUM

BREAKER

FLUSH

CONNECTION

4-3/4”

(121 mm)

±1/2” 

(13 mm)

D

Install the red A-31 Handle Gasket on the Handle Assembly. Insert
the ADA Handle Assembly (B-73-A) into the Handle opening in the
Flushometer Body. Securely tighten the Handle coupling with a
wrench.

HANDLE

ASSEMBLY

HANDLE

COUPLING

A-31 GASKET

D

Install Plug into the Control
Stop by pressing into Bonnet.

A

Make sure Control Stop is
CLOSED and remove
Flushometer Outer Cover.

Reinstall Outside and
Inside Cover wrench
tight. Open Control Stop
to flush supply line. Close
Control Stop and remove
Outside and Inside Cover.

B

Remove Inside Cover and lift
out Inside Parts Assembly.

D

Reinstall Inside Parts Assembly, Inside
Cover and Outside Cover wrench tight.

The Regal XL Flushometer is engineered for quiet operation. Excessive water flow

creates noise, while too little water flow may not satisfy the needs of the fixture.

Proper adjustment is made when the plumbing fixture is cleansed after each flush

without splashing water out from the lip AND a quiet flushing cycle is achieved.

Never open Control Stop to where the flow from the valve exceeds the flow capability

of the fixture. In the event of a valve failure, the fixture must be able to

accommodate a continuous flow from the valve.

!!! IMPORTANT !!!

H

-7

00

 S

ER

IES

 STOP

PLUG

BAK CHEK

®

CONTROL STOP

BONNET

VACUUM

BREAKER

REPAIR KIT

B

Activate Flushometer.

A

Open Control Stop COUNTERCLOCKWISE one FULL turn from
closed position.

C

Adjust Control Stop after
each flush until the rate of
flow delivered properly
cleanses the fixture.

C

3 - INSTALL FLUSHOMETER AND HANDLE ASSEMBLY

4 - FLUSH OUT SUPPLY LINE

5 - ADJUST CONTROL STOP AND INSTALL PLUG