background image

2

1A

ETF-295-A (for EBF-85) Single Hole 4” Trim Plate

A

Slide Rubber Faucet Gasket onto Faucet Shank. Ensure that Roll
Pin on base of Faucet fits into hole in Rubber Faucet Gasket.

FAUCET ROUGH-IN

Note:

When installing with a Sloan Mixing Valve, install Faucet and Trim

Plate before installing Mixing Valve. For complete installation guidelines,
refer to the Installation Instructions supplied with the Sloan mixing valve.

B

Insert Hex Bolts into Black Plastic Base Plate (if sink has only a
center hole, see note above). Place Chrome Cover Plate over
Black Plastic Base Plate. Slide Trim Plate assembly onto Faucet
Shank. Align Roll Pin with small hole in Trim Plate assembly.

Note:

If Trim Plate is used on a sink with a center hole only, Trim Plate

Bolts are not used. Apply plumber’s putty to underside of Trim Plate to
prevent Faucet from rotating.

C

Insert Trim Plate Bolts through the 4 inch (102 mm) spread deck
holes and Faucet Shank through the 1 inch (25 mm) minimum
diameter deck hole. Secure Trim Plate to Deck using the large
Plate Washers and Hex Nuts supplied. Secure Faucet from below
Deck using the Flange Nut supplied.

ROLL PIN

RUBBER
FAUCET GASKET

COVER PLATE

BLACK PLASTIC
BASE PLATE

DECK

FAUCET SHANK

TRIM PLATE
HEX BOLTS (2)

PLATE

WASHERS (2)

HEX NUTS (2)

FLANGE NUT

1

Install Faucet Spout and Trim
Plate — Refer to the appropriate
step (1A-1C) for your application.

EBF-85 and EBF-187 Faucet with Bak-Chek

®

Tee 

for Hot and Cold Water Supply

(shown with 4” trim plate)

EBF-85 and EBF-187 Faucet with ADM Variation

Mixing Valve for Hot and Cold Water Supply

(shown with 8” trim plate)

EBF-85 and EBF-187 Faucet with BDM and BDT

Variation Mixing Valves for Hot and Cold Water

Supply (shown with 4” trim plate)

EBF-85 and EBF-187 Battery Powered Faucet

EBF-85 FAUCET

FAUCET INSTALLATION

Содержание OPTIMA plus Series

Страница 1: ...G IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS FOR THREADED PIPE FITTINGS DO NOT APPLY SEALANT TO THE FIRST TWO STARTER THREADS FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING SOLENOID TO SUPPLY STOPS DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETEL...

Страница 2: ...nderside of Trim Plate to prevent Faucet from rotating C Insert Trim Plate Bolts through the 4 inch 102 mm spread deck holes and Faucet Shank through the 1 inch 25 mm minimum diameter deck hole Secure Trim Plate to Deck using the large Plate Washers and Hex Nuts supplied Secure Faucet from below Deck using the Flange Nut supplied ROLL PIN RUBBER FAUCET GASKET COVER PLATE BLACK PLASTIC BASE PLATE D...

Страница 3: ...all Bracket in an appropriate location as shown in the Rough In illustrations on Page 2 WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW PLASTIC ANCHOR WITH SCREW AND WASHER SHOWN B Position Wall Bracket within 20 inches 508 mm from Faucet When installed the Fiber Optic Cable from the Faucet Spout to the Valve Module should have some slack C Use Wall Bracket Base as a template to mark off holes o...

Страница 4: ... water line connections VALVE MODULE WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW 6 Connect Supply Line s from Supply Stop to Solenoid Valve Inlet C Reattach the Battery Compartment to the Valve Module by aligning the arrow on the Battery Compartment with the arrow on the solid tab of the Valve Module D Secure by tightening Battery Compartment Coupling Ring To deter unauthorized removal of ba...

Страница 5: ...ration procedure should start automatically after proper electrical connections are made Start Up 8 A Remove Spray Head B Open supply stop s then activate Faucet for 30 seconds by placing hands in front of sensor The Solenoid Valve should click the Valve Module should beep and water should flow from the Spout If this does not occur refer to the Troubleshooting section of this instruction instructi...

Страница 6: ... deter unauthorized removal of batteries use a 0 05 hex wrench to tighten the security set screw on the Coupling Ring Upon installation of the batteries the EBF 85 and EBF 187 faucet will begin a new self calibration procedure see START UP MODE SOLENOID SCREEN FILTER CLEANING PROCEDURE A Unscrew the Filter Cap and remove it from the Solenoid Valve Housing and carefully pull the Screen Filter with ...

Страница 7: ...ive SOLUTION Replace Solenoid Valve Module Replace EBF 11 A Solenoid Valve Module INDICATOR Module produces audible BEEPs when a target is placed in the detection zone of the Sensor and Solenoid Valve produces an audible CLICK but NO water flows CAUSE Water supply to faucet is not open SOLUTION Open supply stop s completely CAUSE Bak Chek is installed backward SOLUTION Reinstall Bak Chek properly ...

Страница 8: ...and Sensor Assembly EBF 187 with CP Metal Throat Plate EBF 1009 A Fiber Optic Sensor Cable Assembly Only replaces EBF 12 A includes lens holder 2 ETF 1021 A 0 5 gpm 1 9 Lpm Spray Head with Key female thread ETF 1022 A 2 2 gpm 8 3 Lpm Aerator Spray Head with Key female thread ETF 1027 A 2 2 gpm 8 3 Lpm Laminar Flow Spray Head female thread ETF 435 Replacement Key ONLY for ETF 1021 A and ETF 1022 A ...