4 - CONNECT SENSOR CABLE TO CONTROL MODULE
remove circuit board cover from control module.
route sensor cable from spout to the control module, usually located
under the faucet with sufficient slack in sensor cable. insert locking
connector from faucet spout into mating receptacle on connector board
of control module.
insert the sensor cable into the strian relief slot in the control module.
install circuit board cover into control module.
5 - CONNECT SUPPLY LINE FROM SOLENOID VALVE OUTLET TO FAUCET
For moDEl EBF-625 – install the 1/4” (6.4 mm) pipe to the 3/8”
(9.5 mm) tube compression fitting on spout’s pipe nipple.
For moDEl EBF-655 – install the 1/8” (3.2 mm) pipe to the 3/8”
(9.5 mm) tube compression fitting on spout’s pipe nipple.
For moDElS EBF-625 aND EBF-655 – Connect 3/8” (9.5 mm) outside
diameter (o.D.) of supply tube (furnished by installer) between the
compression fitting on the spout’s pipe nipple and the top outlet
compression fitting on the solenoid valve.
A
B
C
D
A
B
1/4" NPT PIPE
TO 3/8’’ TUBE
COMPRESSION
FITTING
1/4" PIPE NIPPLE
3/8" SUPPLY TUBE
(NOT SUPPLIED)
SOLENOID
VALVE
3/8" TEE COMPRESSION
FITTING
3/8" SUPPLY TUBE
(NOT SUPPLIED)
3/8" SOLENOID VALVE
COMPRESSION FITTING
(TOP OUTLET)
3/8" SOLENOID VALVE
COMPRESSION FITTING
(BOTTOM INLET)
1/8" PIPE TO 3/8"
TUBE COMPRESSION
FITTING
1/8" PIPE NIPPLE
3/8" SUPPLY TUBE
(NOT SUPPLIED)
SOLENOID
VALVE
3/8" TEE COMPRESSION
FITTING
3/8" SUPPLY TUBE
(NOT SUPPLIED)
3/8" SOLENOID VALVE
COMPRESSION FITTING
(TOP OUTLET)
3/8" SOLENOID VALVE
COMPRESSION FITTING
(BOTTOM INLET)
6 - CONNECT SUPPLY LINE(S) FROM SUPPLY STOP TO SOLENOID VALVE INLET
NoTE: Supply stops should be furnished by installer.
Flush dirt, debris, and sediment from the supply line(s).
For Dual liNE hoT aND ColD waTEr Supply appliCaTioNS –
when connecting the faucet to a hot and cold water supply, a Bak-Chek
is required as described in Step 1. if Bak-Chek is not installed at this
time, install them now referring back to Step 1 for instructions.
install a 3/8” copper supply tube between Bak-Chek Compression Tee
Fitting supplied.
install a 3/8” copper supply tube between compression tee fitting and the
bottom inlet compression fitting of solenoid valve.
For SiNglE liNE waTEr Supply appliCaTioNS – when connecting the
faucet to a single line water supply or a pre-tempered water supply, no
Bak-Chek is required.
install a 3/8” copper supply tube between the supply stop and the bottom
inlet compression fitting of solenoid valve.
A
B
C
NoTE: an arrow on the body of the solenoid valve
indicates the water flow direction.
imporTaNT: Keep thread sealant out of your waterway and
prevent component part damage! Do NoT uSE sealant on
compression fittings. when thread sealant is used, Do NoT apply
it to the first two “starter” threads.