background image

5

OTHER VALVE COMPONENT PARTS

Item Code

Part

No. No.

No.

Description

9. 3325814

EBV-1017-A

Handle Cap — Metal

10. 3325815

EBV-1018-A

Handle Cap — Decorative

11. 3323182

V-651-A

Vacuum Breaker Repair Kit

12. 0393004

V-600-A

¾'' (19 mm) x 9'' (229 mm) CP Vacuum Breaker

0393006

V-600-A

1¼'' (32 mm) x 9'' (229 mm) CP Vacuum
Breaker

0393007

V-600-A

1½'' (38 mm) x 9'' (229 mm) CP Vacuum
Breaker

13. 0306125

F-5-A

¾'' (19 mm) CP Spud Coupling

0306140

F-5-A

1¼'' (32 mm) CP Spud Coupling

0306146

F-5-A

1½'' (38 mm) CP Spud Coupling

14. 0308676

H-550

CP Stop Coupling

15. 0308801

H-551-A

CP Adjustable Tailpiece 2-1/16'' (52 mm) long

16. 5308696

H-553

O-ring — 24 per package

17. 3308386

H-700-A

1'' (25 mm) Screwdriver Bak-Chek

®

Stop CP —

complete

3308384

H-700-A

¾'' (19 mm) Screwdriver Bak-Chek

®

Stop CP —

complete

18. 3308853

H-541-A

Control Stop Repair Kit †

3308856

H-543-A

Control Stop Repair Kit ‡

19. 0308612

H-622

CP Bonnet †

0308843

H-577

CP Bonnet ‡

20. 3308791

H-1010-A

Vandal Resistant Control Stop Cap Assembly †

3308790

H-1009-A

Vandal Resistant Control Stop Cap Assembly ‡

21. 3325816

EBV-1019-A

¾'' (19 mm) Decorative Stop Cap

3308866

H-574

1'' (25 mm) Decorative Stop Cap

Accessories

22. 0325107

EBV-91

Trimpot Adjustment Screwdriver

23. 0325823

EBV-22

Disposable Strap Wrench

† For use w/H-700-A 1'' & ¾'' and H-600-A 1'' Screwdriver Bak-Chek

®

Control Stops.

‡ For use w/H-600-A ¾'' Screwdriver Bak-Chek

®

Control Stops.

18

17

21

16

20

19

15

14

10

9

12

11

13

S E N S O R   O P E R A T E D   F L U S H O M E T E R S

Battery Replacement

When OPTIMA 

Plus

has approximately 4,000 flushes left, the same red

light that appears at start-up will flash four (4) times quickly whenever an
object is detected. When this occurs, we recommend changing the
batteries.

Separate Locking Ring, Cover and Flex Tube Diaphragm from Electronic
Sensor Module.

Loosen Retaining Screw on Battery Compartment Door and remove Battery
Compartment Door. Install four (4) Alkaline, AA Batteries 

exactly

as

illustrated. Install Battery Compartment Door and secure with Retaining
Screw. Make certain that Battery Compartment Door is fully compressed
against Gasket to provide a seal; Do Not overtighten.

For all Optima 

Plus

produced from 1992 - 2003

And Regal Pro Optima 

Plus

produced after May, 2003