II.. SSeennssoorr FFllaasshheess CCoonnttiinnuuoouussllyy OOnnllyy W

Whheenn UUsseerr SStteeppss W

Wiitthhiinn RRaannggee..

A. Unit in Start-Up mode; no problem. This feature is active for the first 10

minutes of operation.

IIII.. VVaallvvee DDooeess NNoott FFlluusshh;; SSeennssoorr NNoott PPiicckkiinngg UUpp UUsseerr..

A. Range too short; increase the range.
B. OPTIMA 

Plus

installed on a high rough-in fixture (beam is shooting over

the user's head). Install the Sloan EBV-46-A Beam Deflector (black
modules only).

IIIIII.. VVaallvvee DDooeess NNoott FFlluusshh;; SSeennssoorr PPiicckkiinngg UUpp OOppppoossiittee W

Waallll oorr SSuurrffaaccee,, oorr

OOnnllyy FFlluusshheess W

Whheenn SSoom

meeoonnee W

Waallkkss BByy.. RReedd LLiigghhtt FFllaasshheess

CCoonnttiinnuuoouussllyy ffoorr FFiirrsstt 1100 M

Miinnuutteess EEvveenn wwiitthh NNoo OOnnee iinn FFrroonntt ooff tthhee

SSeennssoorr..

A. Range too long; shorten range.

B. Sensor is picking up mirror or highly reflective wall or surface in front of

fixture. Install OPTIMA 

Plus

slightly "off-center" (2 to 5 degrees) to

eliminate direct reflection off of mirror or opposite wall or surface.

IIVV.. VVaallvvee DDooeess NNoott FFlluusshh EEvveenn AAfftteerr AAddjjuussttm

meenntt..

A. Range Adjustment Potentiometer set at full "max" or full "min" setting.

Readjust Potentiometer away from full "max" or "min" setting.

B. Batteries completely used up; replace batteries.
C. Problem with Electronic Sensor Module; replace Electronic Sensor

Module.

VV.. UUnniitt FFllaasshheess 44 QQuuiicckk TTiim

meess W

Whheenn UUsseerr SStteeppss W

Wiitthhiinn RRaannggee..

A. Batteries low; replace batteries.

VVII.. VVaallvvee DDooeess NNoott SShhuutt ooffff..

A. Bypass orifice in diaphragm is clogged with dirt or debris, or bypass is

clogged by an invisible gelatinous film due to "over-treated" water.
Remove Flex Tube Diaphragm and wash under running water.
Note: Size of orifice in the Bypass is of utmost importance for the proper
metering of water by the valve. DO  NNOT  EENLARGE  OOR  DDAMAGE  TTHIS

ORIFICE. Replace Flex Tube Diaphragm if cleaning does not correct the
problem.

B. Dirt or debris fouling Stem or Flex Tube Diaphragm. Remove Flex Tube

Diaphragm and wash under running water.

C. Problem with Solenoid. If cleaning does not correct the problem, replace

with new Isolated Solenoid Operator.

VVIIII.. NNoott EEnnoouugghh W

Waatteerr ttoo FFiixxttuurree..

A. Wrong OPTIMA 

Plus

Flex Tube Diaphragm installed; i.e., 1.0 gpf urinal

installed on 3.5 gpf closet fixture. Replace with proper Diaphragm
Assembly.

B. Enlarged Bypass in Diaphragm. Replace with Flex Tube Diaphragm Kit.
C. Control Stop not adjusted properly. Readjust Control Stop.
D. Inadequate volume or pressure at supply. Increase water pressure or

supply (flow) to valve. Consult factory for assistance.

VVIIIIII..TToooo M

Muucchh W

Waatteerr ttoo FFiixxttuurree..

A. Control Stop not adjusted properly. Readjust Control Stop.
B. Wrong OPTIMA 

Plus

Flex Tube Diaphragm installed; i.e., 3.0 gpf model

installed on 1.0 or 1.5 gpf urinal fixture. Replace with proper OPTIMA 

Plus

Diaphragm Assembly.

C. Dirt in Diaphragm Bypass. Clean under running water or replace with new

Flex Tube Diaphragm.

IIXX.. M

Meenn''ss RRoooom

m CClloosseett BBoowwllss UUnnfflluusshheedd..

A. Closet being used as urinal. Angle Sensor slightly off fixture centerline to

detect standing person in front of fixture.

XX.. HHiigghh VVaaccuuuum

m BBrreeaakkeerr IInnssttaallllaattiioonn 

((M

Mooddeell 88111155//88111166)) —

— UUnniitt NNoott FFlluusshhiinngg..

A. EBV-46-A Beam Deflector not installed. Install EBV-46-A Beam Deflector

(black modules only) to divert Sensor beams.

XXII.. EElleem

meennttaarryy SScchhooooll UUrriinnaallss NNoott FFlluusshhiinngg..

A. Unusually short users not being detected. Install EBV-46-A Beam

Deflector (black modules only) to divert Sensor beams.

† 

Note:

Use on Black Modules Only.

BATTERIES

When required, replace batteries with four (4) Alkaline Type AA batteries.
For information and instructions on field converting OPTIMA 

Plus

Module

settings or to activate the Stadium Flush™ Feature in urinal models, see the

Sloan OPTIMA 

Plus

Conversion Guide (0816511).

This manual and the OPTIMA 

Plus

Repair and Maintenance Guide are

available at www.sloanvalve.com

CARE AND CLEANING OF CHROME AND SPECIAL FINISHES

DO NOT

use abrasive or chemical cleaners to clean Flushometers as they

may dull the luster and attack the chrome or special decorative finishes.

Use ONLY soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, the Flushometer should be protected from

any splattering of cleaner. Acids and cleaning fluids can discolor or remove

chrome plating.

Refer to the OPTIMA 

Plus

Flushometer Maintenance Guide for additional

Troubleshooting and Repair Part information.

If further assistance is required, please contact the Sloan Valve

Company Installation Engineering Department at 1-888-SLOAN-14 

(1-888-756-2614).
Manufactured in the U.S.A. by Sloan Valve Company under one or more
of the following patents: U.S. Patents: 4,893,039; 5,169,118; 5,244,179;
5,295,655; Des. 345,113; Des. 355,478. Other Patents Pending. BAK-
CHEK

®

, PARA-FLO

®

, PERMEX

®

, TURBO-FLO

®

.

Troubleshooting and Maintaining the Sloan OPTIMA 

Plus

Flushometer

SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131

Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com

Copyright © 2003 Sloan Valve Company                     Printed in the U.S.A.                       Made in the U.S.A.                    OPTIMA PLUS M.G. — Rev. 2 (09/03)                  Code No. 0816193

S E N S O R   O P E R A T E D   F L U S H O M E T E R S

FOR USE WITH SLOAN’S ORIGINAL OPTIMA 

PLUS

FLUSHOMETER PRODUCED FROM 1992 - 2003

COUNTERCLOCKWISE

CLOCKWISE

Decreases

Range

Increases

Range

EBV-46-A BEAM

DEFLECTOR †