background image

Code No. 0816549

Rev. 1 (07/08)

INSTALLATION INSTRUCTIONS FOR

SENSOR ACTIVATED ELECTRONIC SOAP DISPENSER

LIMITED WARRANTY

Sloan Valve Company warrants its ESD-200, ESD-250, ESD-300 and ESD-350 Electronic Soap Dispensers to be made of first class materials, free from defects of
material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed
and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace
any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this
warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve
Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries (Models ESD-250 and ESD-350).

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY
CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

Model ESD-200

Deck Mounted
Plug-in Adapter Powered
Sensor Activated
Electronic Soap Dispenser

Model ESD-250

Deck Mounted
Battery Powered
Sensor Activated
Electronic Soap Dispenser

Model ESD-300

Deck Mounted
Plug-in Adapter Powered
Sensor Activated
Electronic Soap Dispenser
with Chrome Throat Plate

Model ESD-350

Deck Mounted
Battery Powered
Sensor Activated
Electronic Soap Dispenser
with Chrome Throat Plate

For Soap Replenishment use:

Sloan Part # Description

ESD-217 — 800 ml. bottle of Lotion Soap

ESD-232 — 1600 ml. bottle of Lotion Soap

ESD-231 — 800 ml. bottle of Anti-bacterial Soap

ESD-233 — 1600 ml. bottle of Anti-bacterial Soap

Can also be used with TC

®

OneShot

®

Soap Cartridges (refer to Page 6

for TC Stock Numbers)

To order Replacement Soap Cartridges:

1-866-700-CLEAN (1-866-700-2532)
Or go to our website: www.optimasoap.com

Refills are also available through your local plumbing or janitorial
supply distributor.

PRIOR TO INSTALLATION

New Soap Dispenser Installation:
• Locate position of soap dispenser using rough-in diagrams and

template on Pages 2 and 3

• Ensure that soap dispenser does not interfere with anything above

or below the lavatory/counter top area (refer to Pages 2 and 3)

• Drill a 1” diameter hole in counter top (use template on Page 3)
• Clean area around hole

Replacing Existing Soap Dispenser:
• Remove old components
• Clean Area around hole
• Ensure that hole is 15/16” to 1-1/4” diameter

Please take the time to read this manual to ensure proper product installation and longevity. Also, please visit our website

to download our most recent documentation for this product.

If you have questions about how to install your Sloan Flushometer, consult your local Sloan Representative or call

Sloan Installation Engineering Department at:

1-888-SLOAN-14 (1-888-756-2614)

Содержание ESD-200

Страница 1: ... Activated Electronic Soap Dispenser Model ESD 300 Deck Mounted Plug in Adapter Powered Sensor Activated Electronic Soap Dispenser with Chrome Throat Plate Model ESD 350 Deck Mounted Battery Powered Sensor Activated Electronic Soap Dispenser with Chrome Throat Plate For Soap Replenishment use Sloan Part Description ESD 217 800 ml bottle of Lotion Soap ESD 232 1600 ml bottle of Lotion Soap ESD 231 ...

Страница 2: ...25 mm 3 5 16 84 mm 6 15 16 176 mm 14 1 16 357 mm 1 5 8 41 mm 2 31 32 75 mm FLANGE NUT FLANGE NUT 1 8 3 mm S IN K COUNTER FLANGE NUT 4 1 4 108 mm 1 13 16 46 mm SENSOR SOAP DISPENSER ROUGH IN FAUCET SOAP DISPENSER HOT WATER SUPPLY COLD WATER SUPPLY ETF 299 A 2 PIECE TRIM PLATE INSTALLATION The ESD 200 250 300 350 Soap Dispenser oftentimes can be mounted in the left or right hole of a 4 or 8 center s...

Страница 3: ...to a computer printer make certain that the template is the correct size before using Measure to make certain that the 1 1 2 38 mm dimension shown on this template is correct If the dimension measures less than 1 1 2 38 mm do one of the following Reprint this template page making certain that all references to Shrinking oversized pages to paper size or Fit to page are unchecked in the Print window...

Страница 4: ...o red reset button is accessible D Push the motor assembly up into place and secure by pushing the C clip closed E Plug sensor connector into motor assembly and slide rubber seal into place SENSOR CORD MOTOR ASSEMBLY C CLIP BATTERY PACK CUTAWAY VIEW BATTERY PACK CORD A Place battery pack in a convenient location ensuring easy access B Secure to wall with screws and anchors Note The battery pack ma...

Страница 5: ...ttle and initiate the counting mechanism RESET BUTTON As the user s hands enter the beam s effective range the beam is reflected back into the sensor receiver and activates the solenoid valve allowing a single soap application to flow from the spout Flashing RED light in the sensor window indicates low refill Flashing YELLOW light in the sensor window indicates low battery Models ESD 250 ESD 350 o...

Страница 6: ...an Valve Company Installation Engineering Department at 1 888 SLOAN 14 1 888 756 2614 The information contained in this document is subject to change without notice 2B 7 4 8 6 SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 9 VALVE 9 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloanvalve com Copyright 2010 SLOAN VALVE COMPANY Code No 0816549 Rev 2 08 10 I...

Отзывы: