1 - Install Spout

2 - Attach Motor Assembly

A

Slide Rubber Gasket onto Brass Shank making certain that
hole in Gasket is positioned over Spring Pin in Base of Spout
(where applicable).

3 - Attach Battery Pack (Models ESD-250 & ESD-350 Only)

A

Slide C-clip to open position.

D

Guide Sensor Cord through Flange Nut. Screw Flange Nut onto
Brass Shank and tighten.

C

Position Spout to direct soap into sink.

B

Guide Brass Shank and Sensor Cord through hole in counter.

RUBBER
GASKET

BRASS
SHANK

FLANGE NUT

SENSOR CORD

MOTOR

ASSEMBLY

C-CLIP

B

Place motor assembly at
bottom of shank.

C

Rotate motor
housing to avoid
lavatory bottom and
existing plumbing.
Position motor
housing so red reset
button is accessible.

D

Push the motor assembly up into place and secure by pushing the
C-clip closed.

E

Plug sensor connector into motor assembly and slide rubber seal
into place.

SENSOR
CORD

MOTOR

ASSEMBLY

C-CLIP

BATTERY PACK

(CUTAWAY VIEW)

BATTERY PACK CORD

A

Place battery pack in a convenient
location ensuring easy access.

B

Secure to wall with screws and anchors.
Note: The battery pack may be 
mounted using one screw and anchor
with the top slot facilitating easy
removal for battery replacement. A
foam gasket is applied to the back to
seal screw holes.

C

Install 4 alkaline D-size batteries.

D

Connect the power cord
from the battery pack by
inserting then screwing
clockwise into inlet on
top of motor assembly.

4

RESET

BUTTON

RESET

BUTTON

E

Wall clip set may be
used to hold the power
cord against the wall.

SENSOR
CONNECTOR

MOTOR

ASSEMBLY

CORD

Содержание ESD-200

Страница 1: ... Activated Electronic Soap Dispenser Model ESD 300 Deck Mounted Plug in Adapter Powered Sensor Activated Electronic Soap Dispenser with Chrome Throat Plate Model ESD 350 Deck Mounted Battery Powered Sensor Activated Electronic Soap Dispenser with Chrome Throat Plate For Soap Replenishment use Sloan Part Description ESD 217 800 ml bottle of Lotion Soap ESD 232 1600 ml bottle of Lotion Soap ESD 231 ...

Страница 2: ...25 mm 3 5 16 84 mm 6 15 16 176 mm 14 1 16 357 mm 1 5 8 41 mm 2 31 32 75 mm FLANGE NUT FLANGE NUT 1 8 3 mm S IN K COUNTER FLANGE NUT 4 1 4 108 mm 1 13 16 46 mm SENSOR SOAP DISPENSER ROUGH IN FAUCET SOAP DISPENSER HOT WATER SUPPLY COLD WATER SUPPLY ETF 299 A 2 PIECE TRIM PLATE INSTALLATION The ESD 200 250 300 350 Soap Dispenser oftentimes can be mounted in the left or right hole of a 4 or 8 center s...

Страница 3: ...to a computer printer make certain that the template is the correct size before using Measure to make certain that the 1 1 2 38 mm dimension shown on this template is correct If the dimension measures less than 1 1 2 38 mm do one of the following Reprint this template page making certain that all references to Shrinking oversized pages to paper size or Fit to page are unchecked in the Print window...

Страница 4: ...o red reset button is accessible D Push the motor assembly up into place and secure by pushing the C clip closed E Plug sensor connector into motor assembly and slide rubber seal into place SENSOR CORD MOTOR ASSEMBLY C CLIP BATTERY PACK CUTAWAY VIEW BATTERY PACK CORD A Place battery pack in a convenient location ensuring easy access B Secure to wall with screws and anchors Note The battery pack ma...

Страница 5: ...ttle and initiate the counting mechanism RESET BUTTON As the user s hands enter the beam s effective range the beam is reflected back into the sensor receiver and activates the solenoid valve allowing a single soap application to flow from the spout Flashing RED light in the sensor window indicates low refill Flashing YELLOW light in the sensor window indicates low battery Models ESD 250 ESD 350 o...

Страница 6: ...an Valve Company Installation Engineering Department at 1 888 SLOAN 14 1 888 756 2614 The information contained in this document is subject to change without notice 2B 7 4 8 6 SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 9 VALVE 9 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloanvalve com Copyright 2010 SLOAN VALVE COMPANY Code No 0816549 Rev 2 08 10 I...

Отзывы: