background image

INSTALLATION INSTRUCTIONS FOR RETROFIT 

AND COMPLETE SLOAN ECOS

® 

VALVE INSTALLATION

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship 

for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of purchase. During this period, Sloan Valve 

Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole 

and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. 

This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does 

not cover the life of the batteries.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE 

COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

Prior to installing the Sloan ECOS

®

 Electronic Flushometer, install the items 

listed below as illustrated in the Rough-in Diagram. (New installations only.)

•  Closet fixture

•  Drain line

•  Water supply line

Important:

•  ALL PLUMBING SHOULD BE INSTALLED IN 

ACCORDANCE WITH APPLICABLE CODES AND 

REGULATIONS.

•  WATER SUPPLY LINES MUST BE SIZED TO PROVIDE 

AN ADEQUATE VOLUME OF WATER FOR EACH 

FIXTURE.

•  WHEN INSTALLING A FLUSHOMETER, IT IS 

IMPORTANT THAT THE FLUSH MODEL MATCHES 

THE REQUIREMENTS OF THE PLUMBING FIXTURE.

•  FLUSH ALL WATER LINES PRIOR TO MAKING 

CONNECTIONS.

The Sloan ECOS

®

 is designed to operate with 15 to 80 PSI (103 to 552 

kPa) of water pressure. 

THE MINIMUM PRESSURE REQUIRED TO THE VALVE 

IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.

 

Consult fixture manufacturer for pressure requirements.

Most High Efficiency water closets require a minimum flowing pressure of 

25 psi (172 kPa). Many building codes and the ASME A112.19.2 fixture 

standard list Maximum static water pressure as 80 PSI (552 kPa). 

8100 HET/HEU Complete Flushometer Models

8100 Series Sloan ECOS

®

 Electronic Flush valves are complete 

Flushometer valves and ideal for new installations.

RESS Series Retrofit Conversion Kit Models

    RESS Sloan ECOS

®

 Electronic models are used to convert existing Royal, 

Sloan, and Regal style Flushometers to sensor operation.

Sloan ECOS

®

 Electronic Dual Flush Water Closet & Urinal 

Models are furnished for the following:

1.6 gpf/1.1 gpf (6.0 Lpf/4.2 Lpf)  For Low Consumption Bowls
1.28 gpf/1.1 gpf (4.8 Lpf/4.2 Lpf) For High Efficiency Bowls
0.5 gpf/1.9 Lpf For Washdown Urinals
0.25 gpf/1.9 Lpf For High Efficiency Urinals
0.125 gpf/1.9 Lpf For High Efficiency Urinals

1

2

Code No. 0816721

Rev.11 (04/21)

 PRIOR TO INSTALLING THE SLOAN ECOS

®

 DUAL-FLUSH ELECTRONIC FLUSHOMETER

TOOLS REQUIRED FOR INSTALLATION

•  Slotted screwdriver to adjust control stop.

•  Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench for couplings.

•  Trimpot adjustment screwdriver (supplied) to adjust range, if necessary.

•  Strap wrench (supplied) to install Sloan ECOS

®

 Electronic to valve body.

•  7/64” hex wrench (supplied) to secure Sloan ECOS

®

 Electronic cover to base plate.

Reducing Your Water Footprint™

Содержание ECOS HET 8100 Series

Страница 1: ...WHEN INSTALLING A FLUSHOMETER IT IS IMPORTANT THAT THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS The Sloan ECOS is designed to oper...

Страница 2: ...allation Model 8110 8111 Reference for RESS C Retrofit Model 8115 8116 valves are designed for installations where the water supply is roughed in 24 27 610 mm 686 mm above the top of the water closet...

Страница 3: ...Sweat solder the Adapter to pipe WITH THE EXCEPTION OF CONTROL STOP INLET DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING IMPORTANT BAK CHEK CONTROL STOP COVER TUBE IRON...

Страница 4: ...and Spud Flange over Vacuum Breaker Tube B Insert Tube into Fixture Spud C Hand tighten Spud Coupling onto Fixture Spud G 44 FRICTION RING C L SUPPLY ADJUSTABLE TAILPIECE C L FIXTURE CONTROL STOP O RI...

Страница 5: ...fitting the Optima Plus onto a Zurn valve body a special Locking Ring must be used identified by a machined groove around the ring Order the Optima Plus with the Z variation to receive the unit suppli...

Страница 6: ...w may not satisfy the needs of the fixture Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved...

Страница 7: ...xture Replace with proper G2 ECOS model or refer to the G2 ECOS Conversion Guide to convert existing unit to the proper model D Dirt in diaphragm bypass Clean under running water or replace flex tube...

Страница 8: ...ete Sloan ECOS Valves Only 17 H 633 AA Sweat Solder Kit 18 H 700 A Bak Chek Control Stop 19 H 1010 A Vandal Resistant Stop Cap 20 EBV 36 A Valve Body 21A V 600 AA 1 38 mm x 10 254 mm Vacuum Breaker Mo...

Отзывы: