CONFIGURE VACUUM BREAKER AND FLUSH CONNECTION AND CONNECT TO VALVE

A

If needed, trim bottom of adjustable tube using cutter
            • NOTE: would only be needed for certain ADA
               water closet installations.
            • Consult rough-in guide (page 2-3)
As needed based on rough-in, pre-bend the adjustable tube to 
account for side-to-side misalignment of water supply pipe relative 
to fixture spud.

B

C

D

Cut F-1 flush connection to length as needed for particular rough-in.
            • Consult rough-in

Connect F-1 flush connection and adjustable tube to the elbow 
using coupling and poly washer. Apply Loctite® to tube, tighten 
coupling securely.

Cut as needed

B

Adjustable Tube

Coupling 
nut

Poly washer

Elbow

Taper towards 

elbow

Poly washer

Taper towards 

elbow

F-1 Flush Connection

Coupling nut

E

Insert V-651 vacuum breaker into V-560-A vacuum breaker casing.
Attach to valve hand tight.

Attach flush connection to vacuum breaker.

F

G

For hardwire use only: insert conduit and tightly secure it to the wall 
box. Run transformer wires through the conduit to the wall box.

NOTE: TRANSFORMER NOT PROVIDED.  IT IS VERY 
IMPORTANT THAT THE OUTPUT VOLTAGE OF THE 
TRANSFORMER BE 6VAC FOR THE UNIT TO FUNCTION 
PROPERLY.  SLOAN EL-386 OR EL-451 IS RECOMMENDED.

Finish wall. Use supplied mud guard to protect valve during finishing 
process. 
        • Use two (2) mounting screws, if needed, to hold mud   
           guard to wall box
        • Use the marks on mud guard to make sure finished wall   
           is between 3 ¼” and 4 ¼” from the center line of the pipe.

Note: Wall plate opening must be a minimum 7-3/8” wide x 8-3/8” 
tall (187 mm wide x 213 mm tall) to maximum 7-5/8” wide x 
8-5/8” tall (194 mm wide x 219 mm tall)

Vacuum Breaker

V-560-A vacuum 

Breaker casing

Flush Connection

           Loosen vacuum breaker to valve.
           Partially mount fixture onto carrier bolts.
           Pull flush connection forward through wall.
           Make spud connection wrench tight.
                    • NOTE: Space permitting or chase present, spud     
                       connection can be made behind wall.
           Push fixture back to wall. Tighten carrier bolts and complete   
           fixture installation.
           Re-connect vacuum breaker to valve.

A

B

C

D

E

F

A, F

B

E

D

C

FOR WALL HUNG REAR SPUD FIXTURES 
(WATER CLOSETS)

H

Содержание CX 8158-1.28

Страница 1: ...lushometers CX 8158 1 6 CX 8158 1 28 ITEMS INCLUDED VALVE BOX 1 Valve Box 2 Mud Guard 3 Adjustment tool 4 Mud Guard Screws 5 Activation Assembly Screws 6 Instructions 7 Adjustable Tube 8 Outlet Connec...

Страница 2: ...ELECTED Consult fixture manufacturer for minimum pressure requirements Most Low Consumption water closets 1 6 gpf 6 0 Lpf require a minimum flowing pressure of 25 psi 172 kPa Model 8158 Closet Wall Hu...

Страница 3: ...W FRONT VIEW Model 8158 Closet Floor Mount Rear Inlet Roughin for Sloan CX is determined relative to the spud connection for the fixture being used THIS PRODUCT CONTAINS MECHANICAL COMPONENTS THAT ARE...

Страница 4: ...uard Metal C Bracket Wall Bracket Outlet Connection Gasket Poly Washer Elbow Poly Washer Coupling Adjustable Tube V500A RB Vacuum Breaker Assembly Vacuum Breaker Kit Valve Body Wall Box Shut off Sleev...

Страница 5: ...T EXERT FORCE ON WALL BOX TO TIGHTEN FLUSHOMETER USED FIXED JAW WRENCH TO HOLD THE VALVE For hardwire use only remove wall box knock cap closest to the conduit connection E Using a sweat union not sup...

Страница 6: ...secure it to the wall box Run transformer wires through the conduit to the wall box NOTE TRANSFORMER NOT PROVIDED IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER BE 6VAC FOR THE UNIT T...

Страница 7: ...eaker casing Flush Connection Wall opening 1 If needed trim urinal flush tube 2 Slide 3 4 coupling over urinal flush tube If cutting tube thread adapter first then cut After cut remove adapter to help...

Страница 8: ...press until fully seated Remove screws CLOSE E1 E2 B2 B1 C B3 D D G H G1 OPEN CLOSE G Reinstall Collar Collar will spin freely in valve body when properly installed H Using adjustment tool turn activa...

Страница 9: ...Blue terminal block to the two pins in the back of the Sensor Assembly IMPORTANT SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDED iii iv One EL 386 Transformer sold separately serves one 1 CX Clo...

Страница 10: ...l bracket is positioned plumb and level before tightening the screws completely The Sloan CX sensor assembly is designed to work with both hardwire and battery as a back up or only the battery power c...

Страница 11: ...seconds After 10 seconds step away from the sensor and listen for a CLICK The factory setting should be satisfactory for most installations If a range adjustment is required refer to the range adjustm...

Страница 12: ...e Make sure Wall Plate doesn t slide up A B C OPERATION A continuous INVISIBLE light beam is emitted from the Sloan CX Sensor After the user enters the beam s effective range 22 to 31 inches 559 mm to...

Страница 13: ...solenoid connector from the sensor assembly C Shut off water use adjustment tool to turn activation assembly fully clockwise Pass solenoid wire through center of tool to avoid damage Remove tool when...

Страница 14: ...Times When User Steps Within Range Battery Only i Batteries low replace batteries F Red Light Blinks four 4 Times When User Steps Within Range Hardwire and Battery i Battery box not connected connect...

Страница 15: ...306392PK Elbow 6 3306002 1 1 2 Coupling with S 21 Gasket 7 0306031PO 1 1 2 38 mm Flanged outlet tube RB 6 8 0396669PK F 102 1 1 2 38 mm Outlet Tube CP 8 9 0306238PK F 7 Flange CP 10 0306146PK F 5 A 1...

Отзывы: