6
CONFIGURE VACUUM BREAKER AND FLUSH CONNECTION AND CONNECT TO VALVE
A
If needed, trim bottom of adjustable tube using cutter
• NOTE: would only be needed for certain ADA
water closet installations.
• Consult rough-in guide (page 2-3)
As needed based on rough-in, pre-bend the adjustable tube to
account for side-to-side misalignment of water supply pipe relative
to fixture spud.
B
C
D
Cut F-1 flush connection to length as needed for particular rough-in.
• Consult rough-in
Connect F-1 flush connection and adjustable tube to the elbow
using coupling and poly washer. Apply Loctite® to tube, tighten
coupling securely.
A
Cut as needed
B
Adjustable Tube
Coupling
nut
Poly washer
Elbow
Taper towards
elbow
Poly washer
Taper towards
elbow
F-1 Flush Connection
Coupling nut
E
Insert V-651 vacuum breaker into V-560-A vacuum breaker casing.
Attach to valve hand tight.
Attach flush connection to vacuum breaker.
F
G
For hardwire use only: insert conduit and tightly secure it to the wall
box. Run transformer wires through the conduit to the wall box.
NOTE: TRANSFORMER NOT PROVIDED. IT IS VERY
IMPORTANT THAT THE OUTPUT VOLTAGE OF THE
TRANSFORMER BE 6VAC FOR THE UNIT TO FUNCTION
PROPERLY. SLOAN EL-386 OR EL-451 IS RECOMMENDED.
Finish wall. Use supplied mud guard to protect valve during finishing
process.
• Use two (2) mounting screws, if needed, to hold mud
guard to wall box
• Use the marks on mud guard to make sure finished wall
is between 3 ¼” and 4 ¼” from the center line of the pipe.
Note: Wall plate opening must be a minimum 7-3/8” wide x 8-3/8”
tall (187 mm wide x 213 mm tall) to maximum 7-5/8” wide x
8-5/8” tall (194 mm wide x 219 mm tall)
Vacuum Breaker
V-560-A vacuum
Breaker casing
Flush Connection
Loosen vacuum breaker to valve.
Partially mount fixture onto carrier bolts.
Pull flush connection forward through wall.
Make spud connection wrench tight.
• NOTE: Space permitting or chase present, spud
connection can be made behind wall.
Push fixture back to wall. Tighten carrier bolts and complete
fixture installation.
Re-connect vacuum breaker to valve.
A
B
C
D
E
F
A, F
B
E
D
C
FOR WALL HUNG REAR SPUD FIXTURES
(WATER CLOSETS)
H