background image

SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131

Phone: 1.800.982.5839 or 1.847.671.4300 • Fax: 1.800.447.8329 or 1.847.671.4380 • sloan.com

COPYRIGHT © 2018 SLOAN VALVE COMPANY 

 

 

Code No: XXXXXXXX – Rev. 1 (09/18)

 2

 1

Item No.

Part No.

Description

1

See Table

Piston Assembly

2

See Table

Activation Assembly

REPAIR ITEMS

15

Code No.

Description

Plug Color*

3340048

1.6 gpf/6.0 Lpf closet activation assembly

Green

3340049

1.28 gpf/4.8 Lpf closet activation assembly

Purple

3340051

0.5 gpf/1.9 Lpf urinal activation assembly

Red

3340052

0.25 gpf/1.0 Lpf urinal activation assembly

Burgundy

ACTIVATION ASSEMBLY SELECTION GUIDE

Colors may differ. Consult factory to confirm you have the correct piston assembly.

Item

Code No.

Description

1

0323011

V-500A Vacuum Breaker

2

0323279

Short Vacuum Breaker Tube

3

0306394

Adjustable Tube

4

0306395

Poly Washer Coupling (set of two)

5

0306392PK

Elbow

6

3306002

1-1/2" Coupling with S-21 Gasket

7

0306031PO

1 1/2" (38 mm) Flanged outlet tube RB, 6"

8

0396669PK

F-102 1-1/2" (38 mm) Outlet Tube CP 8"*

9

0306238PK

F-7 Flange CP*

10

0306146PK

F-5-A 1-1/2" Spud Coupling Assembly CP*

11

0306396

Urinal Connection

FLUSH CONNECTION PARTS 

The information contained in this document is subject to change without notice.

Manufactured in the U.S.A by Sloan Valve Company under one 

or more of the following patents: U.S. Patents. 5,295,655; 

5,542,718; 5,558,120; 5,564,460; 5,730,415; 5,865,420; 

5,887,848; 5,967,182. Other Patents Pending.  

Bak-Chek

®

, Para-flo

®

, PERMEX

®

, Turbo-Flo

®

* Consult factory for alternate finish options

1

2

3

4

10

5

4

8

7

Install with
Flange against spud

For Model 158, Wall Hung

For Model 158, Floor Mount

9

4

For Model 198

11

Code No.

Description

Piston Color*

3340053

1.6 gpf/6.0 Lpf closet activation assembly

Green

3340054

1.28 gpf/4.8 Lpf closet activation assembly

Purple

3340055

0.5 gpf/1.9 Lpf urinal activation assembly

Red

3340056

0.25 gpf/1.0 Lpf urinal activation assembly

Burgundy

PISTON ASSEMBLY SELECTION GUIDE

Содержание CX 8158-1.28

Страница 1: ...lushometers CX 8158 1 6 CX 8158 1 28 ITEMS INCLUDED VALVE BOX 1 Valve Box 2 Mud Guard 3 Adjustment tool 4 Mud Guard Screws 5 Activation Assembly Screws 6 Instructions 7 Adjustable Tube 8 Outlet Connec...

Страница 2: ...ELECTED Consult fixture manufacturer for minimum pressure requirements Most Low Consumption water closets 1 6 gpf 6 0 Lpf require a minimum flowing pressure of 25 psi 172 kPa Model 8158 Closet Wall Hu...

Страница 3: ...W FRONT VIEW Model 8158 Closet Floor Mount Rear Inlet Roughin for Sloan CX is determined relative to the spud connection for the fixture being used THIS PRODUCT CONTAINS MECHANICAL COMPONENTS THAT ARE...

Страница 4: ...uard Metal C Bracket Wall Bracket Outlet Connection Gasket Poly Washer Elbow Poly Washer Coupling Adjustable Tube V500A RB Vacuum Breaker Assembly Vacuum Breaker Kit Valve Body Wall Box Shut off Sleev...

Страница 5: ...T EXERT FORCE ON WALL BOX TO TIGHTEN FLUSHOMETER USED FIXED JAW WRENCH TO HOLD THE VALVE For hardwire use only remove wall box knock cap closest to the conduit connection E Using a sweat union not sup...

Страница 6: ...secure it to the wall box Run transformer wires through the conduit to the wall box NOTE TRANSFORMER NOT PROVIDED IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER BE 6VAC FOR THE UNIT T...

Страница 7: ...eaker casing Flush Connection Wall opening 1 If needed trim urinal flush tube 2 Slide 3 4 coupling over urinal flush tube If cutting tube thread adapter first then cut After cut remove adapter to help...

Страница 8: ...press until fully seated Remove screws CLOSE E1 E2 B2 B1 C B3 D D G H G1 OPEN CLOSE G Reinstall Collar Collar will spin freely in valve body when properly installed H Using adjustment tool turn activa...

Страница 9: ...Blue terminal block to the two pins in the back of the Sensor Assembly IMPORTANT SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDED iii iv One EL 386 Transformer sold separately serves one 1 CX Clo...

Страница 10: ...l bracket is positioned plumb and level before tightening the screws completely The Sloan CX sensor assembly is designed to work with both hardwire and battery as a back up or only the battery power c...

Страница 11: ...seconds After 10 seconds step away from the sensor and listen for a CLICK The factory setting should be satisfactory for most installations If a range adjustment is required refer to the range adjustm...

Страница 12: ...e Make sure Wall Plate doesn t slide up A B C OPERATION A continuous INVISIBLE light beam is emitted from the Sloan CX Sensor After the user enters the beam s effective range 22 to 31 inches 559 mm to...

Страница 13: ...solenoid connector from the sensor assembly C Shut off water use adjustment tool to turn activation assembly fully clockwise Pass solenoid wire through center of tool to avoid damage Remove tool when...

Страница 14: ...Times When User Steps Within Range Battery Only i Batteries low replace batteries F Red Light Blinks four 4 Times When User Steps Within Range Hardwire and Battery i Battery box not connected connect...

Страница 15: ...306392PK Elbow 6 3306002 1 1 2 Coupling with S 21 Gasket 7 0306031PO 1 1 2 38 mm Flanged outlet tube RB 6 8 0396669PK F 102 1 1 2 38 mm Outlet Tube CP 8 9 0306238PK F 7 Flange CP 10 0306146PK F 5 A 1...

Отзывы: