Install Baffle Tee onto 1 1/4" threaded tailpiece using 1 1/2" Slip Joint Nut,
and 1 1/2" x 1 1/4" Slip Joint Washer.
IMPORTANT: Do not tighten drain connections completely until all drain
fittings are in proper position.
Select the taller one of two threaded capped openings on Collection Tank for
Tablet Dispenser.
Unscrew Tablet Dispenser cap and remove.
Insert three cleansing tablets. Replace cap.
WARNING: Read the handling instructions on Tablet package before opening.
After trimming to appropriate lengths, install waste arm to bottom of Baffle
Tee and Tablet Dispenser inlet using 1 1/2" Slip Joint Nut and Slip Joint
Washer. Adjust position of Collection Tank for proper fit.
Connect P-Trap to the wall drain and Baffle Tee side outlet. Additional
provided fittings allow for alternative drain connections. Baffle Tee may need
to be turned to fit to wall drain.