4.4.2
Engine Start
Alternative checklist for aircraft equipped with a Rotax 912 ULS.
1.
Fuel Selector ............................. EMPTIEST TANK
(IF NOT EMPTY)
2.
EFIS Backup Switch ................... ON
(VERIFY BATTERY VOLTAGE)
3.
EFIS Main Switch ...................... ON
4.
ECU Backup Switch ................... ON
5.
Master Switch .......................... ON
6.
Ignition / Lanes ......................... ON
(BOTH)
7.
Auxiliary Fuel Pump .................. ON
(FUEL PRESSURE/ABNORMAL SOUND)
.................. OFF
(AFTER 5 SECONDS)
8.
Main Fuel Pump ....................... ON
(FUEL PRESSURE/ ABNORMAL SOUND)
9.
ECU Backup Switch ................... OFF
10.
Throttle .................................... SET (+ -50%)
11.
Propeller ................................... AREA CLEAR
12.
Starter ...................................... ENGAGE
(MAX. 10 SECONDS)
13.
Oil Pressure .............................. CHECK
(CORRECT WITHIN 10 SECONDS)
14.
Throttle .................................... +/- 2500 RPM
15.
Ignition / Lane Lights ................ VERIFY OFF
16.
Alternator B .............................. CHECK ONLINE
(a)
17.
Avionics Switch ......................... ON
18.
Oil Temperature ....................... 2500 RPM
until oil temperature
.......................
is
< 50 °C (122 °F)
(b)
NOTE
a.
Main bus voltage should move up from +/- 12.5V to above 13V
when the engine RPM is held above/at 2500 RPM for more than
5 seconds. This is the indication that Alternator B has been
brought online by the ECU.
b.
When the oil is below 50 °C, the oil filter is bypassed due to the
increased viscosity of the oil. Significant throttle settings must not
be used during this period, as it may cause damage.