S-link Planning & Precautions

EN

S-link is a ”CAN” based control system with full intelligent communication between all units in the system. 

Main advantages include:

- Round, compact and waterproof plugs with unique keying and colour coding to avoid faulty hookup.

- An unlimited number of commands or information transfer on a single cable.

- Proprietary Sleipner commands but built 100% on NMEA 2000 standard.

Routing the Backbone:

Keep routing backbone spur cables to a minimum. Avoid routing the S-link cables close to equipment that might cause interference to the S-link 

signals such as radio transmitter equipment, antennas or high voltage cables. The backbone MUST be terminated at each end with the 6 1327 End

Terminator.

Spur cables:

Spur cables can be left not terminated 

(NB: Routing can be prepared for future additional equipment)

. Make sure to protect open connectors from

water and moisture to avoid corrosion in the connectors.

MG_0159

S1=_____

BB1=___

BB2=___

S2=_____

Positive, Negative 

& Shield

Example of the control wiring 

with  S-link system for boats 

with one control position and 

one thruster. 

Bow Thruster

Automatic 

Main switch

BACKBONE Cable

Forms the main 

“loop” around the 

boat.

SPUR Cable

Must be used to connect all 

parts to the backbone cable 

(One for each component, no 

exceptions). Recommended to 

be as short as practically 

possible.  

POWER Cable

Must be one in each 

system, length 2.5m

4-Port T Connector

The 4-port T-connector allows multiple spur cables to be 

connected. 

(NB: Comes with two sealing caps to protect.)

T- Connector

Must be one for each spur, 

including power cable 

BACKBONE extender

Connects two BACKBONE 

cables to extend length.

END terminator

Must be one for each end 

of the BACKBONE “loop”.

Power Supply

Control Panel

You need:

2 x 6 1327 End terminators

3 x 6 1326  T-connectors

1 x 6 1328 Power spur

2 x 6 1320-xxM Backbone cables

2 x 6 1321-xxM  Spur cables

Thruster

Control Panel

Backbone cables

Forms the main ”loop” around the boat

Part #: 6 1320-xxM (xx=length)

0,2 m

2,0 m

4,0 m

7,0 m

15,0 m

20,0 m

Spur cables

Must be used to connect all parts to the backbone cable (one for each component, no 

exeptions), recommended to be as short as practically possible

Part #: 6 1321-xxM (xx=length)

0,4 m

1,0 m

3,0 m
5,0 m

Power cable (spur)

Must be one in each system,

delivered in the length of 2,5m

Part #: 6 1328

T-connector

Must be one for each spur,

including the power cable

Part #: 6 1326

End terminator

Must be one in each end 

of the backbone ”loop”
Part #: 6 1327

S-link cable parts

Control

panel

Power 

supply

Automatic

mainswitch

Bow

thruster

Example of wiring

Wiring of S-link system 

Explaining S-link

S-link is a ”CanBus” based control system

with full intelligent communication

between all units in the system, much like

a computer network.

Main advantages include:

-

Round, compact and waterproof plugs with 

unique keying to avoid faulty hookup

-

Unlimited number of commands or information 

transfer on a single cable

-

Proprietary Sleipner commands, but built 100% 

on NMEA 2000 standard

Control Panel Cable Installation

EN

•  

All Sleipner control panels can be used in any combination. 

•  

All control panels can be installed using:

 

• Y-connectors - for standard on/off 

• T-connectors - for S-link proportional power system. 

(NB: If two or more control panels are operated at the same time in opposite directions, the electronic control box will stop the thruster until 

it receives a single signal or thrust in one direction.)

• 

Sleipner on/off equipment it is entirely “plug & play” and require no additional confi guration setup.

See the Control panel manual for more information.

MC_0041

!

 Please refer to the graphic for special considerations relating to your model 

!

MG_0106

**Setup with automatic 

   main switch

**Setup with manual

   main switch

Controller

M

+

-

12V

5A

red

black
yellow

Terminator

120 ohm

Terminator

120 ohm

Retract

panel

Power supply

cable

Retract

thruster

Controller

6 1242

T-connector

T-connector

T-connector

Ac

tu

at

or

Battery

+12V

Automatic

Main Switch

w/S-link

8730

Foot

Switches

( opt.)

Remote control

(opt.)

optional

optional

M

+

-

12V

5A

red

black
yellow

Terminator

120 ohm

Terminator

120 ohm

Retract

panel

Power supply

cable

Retract

thruster

Controller

6 1242

T-connector

T-connector

T-connector

Ac

tu

at

or

Battery

+12V

8730

Foot

Switches

( opt.)

Remote control

(opt.)

Manual main switch 

Main fuse

Supply Voltage

7-31 VDC, Powered 

at B+ & B-

Power consumption Less than 1.5 Watt in 

standby

Fuse @ 12V

40 Amp

Fuse @ 24V

40 Amp

Minimum Voltage at 

B+/B- for deploy-

ment

11.7 Volt for 12 Volt 

thruster

23.4 Volt for 24 Volt 

thruster

Operating temper-

ature

-10°C to 60°C (14°F 

to 140°F)

Weight

500g/17,6oz

Содержание SR-V300

Страница 1: ...SLEIPNER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE Installation Guide For Pro Electric Retractable Thruster Models SRP V300 EN I M 5927 7 2021...

Страница 2: ...nsiderations and Precautions 7 Marking and Trimming of SRF Flange 8 Installation Pre check 9 Required Modifications After Pre check 10 SRF Flange Installation 11 Motor House Installation 12 Hatch Inst...

Страница 3: ...r at close range to easily flammable objects as it will reach over 100 C before the temperature switch is activated Do not store items close to the thruster motor as it can reach 100 C Any loose items...

Страница 4: ...mentary measurement Height 172 6 77 H Motor housing height 452 17 80 MH SRF flange height 115 4 53 RD Retracted hatch supplementary measurement 445 17 52 ID Tunnel diameter 300 11 81 W SRF flange moto...

Страница 5: ...n Flexible coupling between electro motor and drive shaft protects electro motor and gear system if propeller jams Original Sleipner panels shut off automatically 6 minutes after last use Original Sle...

Страница 6: ...r the waterline The thruster while retracted must not conflict with any other component of the vessel such as stern drives propellers trim tabs or rudders Therefore stern installations do not require...

Страница 7: ...oducts or via a Sleipner supplied interface product made for interfacing with other controls Any attempt to directly control or at all connect into the S link control system without the designated and...

Страница 8: ...uster considering space required for installation operation and future maintenance 2 Mark the keel centre line on the inside of the hull Flip the SRF flange upside down and use the internal surface to...

Страница 9: ...the label on actuators for correct voltage to the 6 mm cables on the terminals on the controller Set switch no 4 on the DIP switch marked SETTINGS to ON Remove the wooden safety part located above th...

Страница 10: ...nge and motor stable 3 Open and close the hatch multiple times to ensure Clearance from the hull and hatch while open Hatch closes flush with the hull and extra force is still transferred to the hull...

Страница 11: ...xy and breglass cutting or similar which laminating material is the actual boat builders responsibility Cover the upper part if grinding is necessary After moulding material have cured run the retract...

Страница 12: ...lue is compatible with SRF and thruster case materials 2 Place the upper thruster Housing down on the SRF flange 3 Insert and fasten bolts Start with the 4 corner bolts followed by the remaining to re...

Страница 13: ...cessive material before coating the hatch 9 Apply ller on to tunnel rings contact surface so the hatch will be secured properly Now re install hatch in its correct position Tighten bolts so hatch will...

Страница 14: ...llation later 2 Fasten the bolts holding the motor to the motor bracket with the above torque 3 Check the drive shafts engage by rotating the propeller It is required the propeller can rotate via hand...

Страница 15: ...ube has no loops and forms an airlock to stop the oil flow Ensure the oil tube angle is suf cient to allow oil to flow freely into the gear leg 3 Fill the oil tank with the same gear oil used in the g...

Страница 16: ...ff the thruster independently from the rest of the electrical operation of the vessel when not on board or in emergencies NB It is advised to install a fuse on the positive cable for protection agains...

Страница 17: ...AWG 2 0 2 0 4 0 2 x 2 0 2 x 3 0 2 x 3 0 2 x 4 0 2 x 4 0 2 x 4 0 24 V 280 A DIN 300 SAE 570 EN 520 ANL 250 mm2 35 35 35 50 50 70 70 95 95 120 120 2 x 95 AWG 2 2 2 1 0 1 0 2 0 2 0 3 0 3 0 4 0 4 0 2 x 3...

Страница 18: ...automatic main switch Setup with manual main switch Controller M 12V 5A red black yellow Terminator 120 ohm Terminator 120 ohm Retract panel Power supply cable Retract thruster Controller 6 1242 T con...

Страница 19: ...s short as practically possible POWER Cable Must be one in each system length 2 5m 4 Port T Connector The 4 port T connector allows multiple spur cables to be connected NB Comes with two sealing caps...

Страница 20: ...20 5927 7 2021 SRP 300 MG_0136 EN Visual Wiring Diagram...

Страница 21: ...21 5927 7 2021 SRP 300 MG_0137 EN Visual Wiring Diagram...

Страница 22: ...uator s No 1 set to OFF when the retract has two actuators No 1 set to ON when the retract only has one actuator No 2 set to OFF when the retract does not have P8 type actuator s No 2 set to ON when t...

Страница 23: ...cut out is jagged or chipped use a sealant to assist the gasket 3 Place the gasket to the back face of the panel 4 Plug cables into the connectors at the rear of the control panel 5 Insert the control...

Страница 24: ...house and propeller but NOT anodes sealing rubber ttings or propeller shafts Propeller is fastened correctly to the shaft Propeller turns freely in tunnel The anode and or holding screw is tightened w...

Страница 25: ...e Purchaser at the Warrantor s expense If on the other hand the claim is determined to result from circumstances such as described in section 4 above or a result of wear and tear exceeding that for wh...

Страница 26: ...26 5927 7 2021 SRP 300 MC_0037 Notes EN...

Страница 27: ...27 5927 7 2021 SRP 300 MC_0037 Notes EN...

Страница 28: ...accuracies or omissions it may contain Continuous product improvement may change the product speci cations without notice Therefore Sleipner Motor AS can not accept liability for any possible differen...

Отзывы: