HydroPOD 35 & 50

MG_0080  

H

+H

L

W

WD

Failure to follow the considerations and precautions can cause serious injury, 

damage and will render all warranties given by Sleipner Motor as VOID.

MC_0411

MC_0427

General Installation Considerations and Precautions for SX Thrusters

•  The external thruster assembly and controller unit are ignition protected and can be installed in areas with the chance of explosive gases in     

   accordance to ISO 8846 and ABYC c1500. (Certifi cation pending)

•  Ensure that the external thruster assembly does not disturb the water flow under the hull. At higher speeds, if the thruster is installed to    

low it can cause damage to the thruster and/ or add additional drag and unwanted water splashing. 

•  The recommended minimum tunnel depth from the water surface is 140mm (5,51‘) to the centre of tunnel diameter. Place the Thruster as deep as  

  possible for better performance and reduced noise. 

•  When installing the thruster ensure it does not foul existing equipment inside the boat like motor bedding etc. 

•  If able ensure that stern-drives/ trim-tabs do not interfere with the water flow from the thruster as this can reduce the thrust effectiveness   

  considerably. We recommend the use of our Sleipner cowls to enhance the performance and allow installation in shallow draft boats. Sleipner  

  cowls will also minimise the effect if stern-drives/ trim-tabs obstruct the thruster.

•  Ensure there is enough space both inside and outside the transom of the boat and the thruster does not get in conflict with existing equipment  

  inside the boat like steerage links etc. 

(NB: It is possible to mount the tunnel offset from the boat’s centre line if necessary.)

•  Heat protection cut off is calculated from the thruster motor. To avoid cable overheating do not install place the volt cables from the thruster to the  

  control box near any heat sources.

MC_0007

General User Considerations and Precautions for IP Systems

NEVER Disassemble any part of the Ignition Protected assembly. Tampering with the Ignition Protected assembly will cause it to lose this 

safety feature. If there is a problem with your Ignition Protected motor, please contact your dealer.

MC_0105

Considerations and Precautions for S-Link Systems

When installing an S-Link™ system DO NOT connect any other control equipment directly to the S-Link™ bus except original Sleipner S-Link™ products. 

In case of connecting third-party equipment, it must always be connected through a Sleipner-supplied interface product. 

Any attempt to directly control or connect into the S-Link™ control system without a designated and approved interface will render all warranties and 

responsibilities of all of the connected Sleipner products. 

If you are interfacing the S-Link™ bus by agreement with Sleipner through a designated Sleipner supplied interface, you are still required to install at 

least one original Sleipner control panel to enable efficient troubleshooting if necessary.

Содержание Pro DC External POD

Страница 1: ...ER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE Installation Guide For Pro DC External POD Electric Thruster Models SXP35POD SXP50POD EN I M 6399 1...

Страница 2: ...hruster 12V w Controller Installation Manual Responsibility of the Installer 3 4 Thruster Measurements 5 Thruster Specifications 6 Technical Specifications 6 Control Box Technical Specifications 7 Pos...

Страница 3: ...cument to ensure necessary familiarity with the product before installation Instructions in this document cannot be guaranteed to comply with all international and national regulations It is the respo...

Страница 4: ...ruct the thruster Ensure there is enough space both inside and outside the transom of the boat and the thruster does not get in conflict with existing equipment inside the boat like steerage links etc...

Страница 5: ...L W WD MC_0268 Thruster Measurements Measurement code Measurement description mm inch mm inch H Mould Height 180 7 08 180 7 08 H Tube Height 183 7 20 183 7 20 W Width 183 7 2 183 7 2 L Length 630 24...

Страница 6: ...me lapse device protects against sudden change of drive direction The electric thermal cut off switch in electro motor protects against overheating auto reset when electro motor cools down Original Sl...

Страница 7: ...SX35 SX50 Operation volts 12v 12v Max Current 250A 380A Duty Cycle S2 S2 Max ambient temp 50 c 50 c Min ambient temp 25 c 25 c Power supply cable 35 70mm AWG 2 00 35 70mm AWG 2 00 Mount direction Any...

Страница 8: ...Cover Aim to install the thruster as far forward Aft as possible Due to the leverage effect around the boats pivot point The relative distance difference from the boat pivots point to the thruster wi...

Страница 9: ...074 Grids or Cowls assembly 1 Attach the cowls or grids with included bolts and washers NB If installation of the cowls ensure the appropriate twist of the cowl to direct water away from obstacles MG_...

Страница 10: ...rts 1 2 Tunnel Installation 1 Ensure to remove the plastic cover guard on the tunnel 2 Connect both ends of the tunnel to the thruster motor All hooks must be completely interlocked making the inside...

Страница 11: ...ness is 50mm 2 Drill main hole for the cable tube then two support bolt holes 3 Place the SX thruster into the Hydro pod mould 4 Place the hydro pod with the SX thruster on the hull Use the pre drille...

Страница 12: ...s to length top achieve 15 compression 4 Apply a sealant MS Polymer to IF required to fill gaps between the Hydro pod and the hull use an the inside surface of the cut out holes on the hull appropriat...

Страница 13: ...pin aligns with the internal slot in the propeller 2 Insert the washer to the end of the shaft spline Tighten with the propeller lock nut 3 Apply anti fouling to the gear leg and propeller Do not app...

Страница 14: ...and drill the holes 3 Attach cables to the control box NB the control box internal components can be removed via its attachment screws for easier installation using thick battery cables 4 Tighten hos...

Страница 15: ...electrical operation of the vessel when not on board or in emergencies NB It is advised to install a fuse on the positive cable for protection against short circuiting of the main cables The fuse shou...

Страница 16: ...switch NC NTC Temp switch NC NTC SX50 CONTROL BOX SX35 CONTROL BOX B B Tighten to 5 6 NM 4 13 lb ft Blue Hose Tighten to 5 NM 3 69 lb ft Tighten to 5 NM 3 69 lb ft Tighten to 5 6 NM 4 13 lb ft Tighte...

Страница 17: ...2 0 2 x 2 0 35 140 12 V 245 A DIN 200 SAE 380 EN 330 ANL 150 mm2 35 50 50 70 70 95 95 120 120 2 x 70 2 x 70 2 x 95 AWG 2 1 0 1 0 2 0 2 0 3 0 3 0 4 0 4 0 2 x 2 0 2 x 2 0 2 x 3 0 50 1400 12 V 370 A DIN...

Страница 18: ...g play and require no additional configuration setup See the Control panel manual for more information MC_0041 Please refer to the graphic for special considerations relating to your model MG_0127 Aut...

Страница 19: ...e shall be connected to GND and the red wire connected to 12VDC or 24VDC To reduce the risk of interference avoid routing the S Link cables close to equipment such as radio transmitters antennas or hi...

Страница 20: ...tion For Control Panel installation please refer to the supplied manual in your Sleipner product delivery MC_0398 SLEIPNER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID RE...

Страница 21: ...r house and propeller but NOT anodes sealing rubber fittings or propeller shafts Propeller is fastened correctly to the shaft Propeller turns freely in tunnel The anode and or holding screw is tighten...

Страница 22: ...rned to the Purchaser at the Warrantor s expense If on the other hand the claim is determined to result from circumstances such as described in section 4 above or a result of wear and tear exceeding t...

Страница 23: ...23 6399 11 2021 HydroPOD 35 50 MC_0037 Notes...

Страница 24: ...ccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any possible differen...

Отзывы: