15
6399
11
2021
-
HydroPOD 35 & 50
Control Box Installation
The control box is the central component that can be connected to several other control panels. The control box can be mounted in any orientation,
preferably with cables facing down.
(NB: The control box must be positioned within 0,75 meters from the thruster assembly with the provided
cables and not near any object that radiate high temperatures.)
1. Defi ne the location to install the control box.
(NB: Ensure cables will not obstruct any objects.)
2. Mark the locations of the four drill holes and drill the holes.
3. Attach cables to the control box
(NB: the control box internal components can be removed via its attachment screws for easier installation
using thick battery cables.)
4. Tighten hose clamps in order to ensure Ignition Protection as illustrated.
5. Fasten the control box to the hull.
MC_0075
!
Please refer to the graphic for special considerations relating to your model
!
IMPORTANT
It is the installers full responsibility to follow instructions and ensure total Ignition Protection.
MC_0035
Thruster Electrical Installation
!
Please refer to the graphic for special considerations relating to your model
!
WARNING
Check the following with the main switch is set to off :
After all electrical connections have been completed check with an ohm meter that there is no electrical connection between
1. electro-motor flange and the positive terminal on the motor
2. electro-motor flange and the battery negative terminal on the motor
If unsure contact skilled personnel.
1. Information of electrical table.
see next page
- All power cable lengths represent the total length of the combined (+) and (-) cables.
- Battery capacity is stated as minimum cold crank capacity, (CCA).
- Use slow blow rated fuses to hold stated Amp-Draw for min. 5 minutes.
- Consider the AMP hours (Ah) for your specifi c duty cycle.
2. Use appropriate sized cables and batteries with high cranking capacity to feed the thruster. The actual voltage at the motor while running the
thruster decides the motors output RPM and thrust. Use larger cables and stronger batteries for better results.
- See electrical specifi cations for advised minimum cables and batteries (CCA).
3. Connect the battery supply to the control unit (PPC).
- Install a main manual/ automatic switch from the positive lead terminal on the battery PPC unit). The main switch must be accessible to turn
off the thruster independently from the rest of the electrical operation of the vessel when not on-board or in emergencies.
(NB: It is advised
to install a fuse on the positive cable for protection against short-circuiting of the main cables. The fuse should ensure no voltage
decrease, slow-blow and sized to take the amperage draw for at least 5 minutes.)
- A circuit breaker can be used instead of the fuse and main power switch If the functionality is the same.
(NB: For Ignition Protected installations remember to use ignition protected fuses and switches if fi tted in areas that require this feature.
Ensure to follow your national regulations)
5. Cable lugs must have adequate electrical and mechanical isolation and fi tted with cable lug covers.
6. Fasten cables to the required torque.
MG_0126
8-lead cable
A1
A2
Temp switch
NC
NTC
PPC
Proportional Power
Controller PPC
Min
200mm
Min
100mm
Min
100mm
B+
B-
CONTROLLER
8-lead cable
++
*C
BLUE PROTECTION
SLEVE
(900mm/ 35”)
IP
configuration
Non-IP
configuration
THRUSTER
(MUST BE IGNITION PROTECTED IF
LOCATED IN IP REQUESTED AREA)
Automatic MAIN
SWITCH
THRUSTER
BATTERY
12V
Minimum and recommended cable dimensions can be identical due to safety margins and cable heat considerations for short cable lengths.
* Minimum or recommended cable cross section in mm2
B-
B+
+
-
*D
MAIN FUSE
S-link
spur
cables
S-link
backbone
CONTROLLER CONNECTIONS:
<<B+>>: Power supply pos from thruster battery/ Main switch/ Main fuse
<<B->>: Power supply neg from thruster battery
2 Motor cables from thruster
4 wires from thruster overtemp switch
2 Control cables from control panel(s)/ remote
**Automatic or
Manual main switch
(See Main Switch
installation manual)
Содержание Pro DC External POD