E95.1901EN032 User manual Slant Fin VGH-CH / CO
Blocking
code
Error
Description
Cause
Solving
118
WD_COMM_
ERROR
Watchdog communication
error
wrong
programmed BCU
or PB
If the boiler does not start
after Reset, contact your
installer
119
RETURN_
OPEN
Return sensor open
malfunctioning
return sensor or
not connected
If the boiler does not start
after Reset, contact your
installer
120
SUPPLY_
OPEN
Supply sensor open
malfunctioning
supply sensor or
not connected
If the boiler does not start
after Reset, contact your
installer
122
DHW_OPEN
DHW sensor open
malfunctioning
DHW sensor or not
connected
If the boiler does not start
after Reset, contact your
installer
123
FLUE_OPEN
Flue sensor open
malfunctioning flue
sensor or not
connected
If the boiler does not start
after Reset, contact your
installer
125
OUTDOOR_
OPEN
Outdoor sensor open
malfunctioning
outdoor sensor or
not connected or
wrong CH-mode
programmed
If the boiler does not start
after Reset, contact your
installer
126
RETURN_
SHORTED
Return sensor shorted
malfunctioning
return sensor or
short circuiting
If the boiler does not start
after Reset, contact your
installer
127
SUPPLY_
SHORTED
Supply sensor shorted
malfunctioning
supply sensor or
short circuiting
If the boiler does not start
after Reset, contact your
installer
129
DHW_
SHORTED
DHW sensor shorted
malfunctioning
DHW sensor or
short circuiting
If the boiler does not start
after Reset, contact your
installer
130
FLUE_
SHORTED
Flue sensor shorted
malfunctioning flue
sensor or short
circuiting
If the boiler does not start
after Reset, contact your
installer
132
OUTDOOR_
SHORTED
Outdoor sensor shorted
malfunctioning
outdoor sensor or
short circuiting
If the boiler does not start
after Reset, contact your
installer
133
NET_FREQ_
ERROR
Net freq. error detected by
the watchdog
wrong frequency
from power grid or
aggregate
If the boiler does not start
after Reset, contact your
installer
134
RESET_BUTTO
N_ ERROR
Too many resets in a short
time period
reset too many
times by user or
installer
Wait or disconnect and
reconnect power supply
135
PHASE_NEUTR
AL_ REVERSED
Live and neutral of the
main voltage power supply
input are reversed
phase and neutral
are wrongly
connected
If the boiler does not start
after Reset, contact your
installer
136
T_EXCHANGE_
BLOCK_ERROR
Exchange temperature
exceeded 194 ºF (90 ºC).
water temperature
is above 194 ºF
(90 ºC).
If the boiler does not start
after Reset, contact your
installer
155
WD_CONFIG_
ERROR
Watchdog fan configuration
setting error
wrongly program-
med BCU or PB
If the boiler does not start
after Reset, contact your
installer
162
FILL_WARNING
Error generated directly
when pressure drops
below Minimal_Pressure.
Demand has stopped, but
no error is to be stored at
this time.
the water pressure
is below the
minimum pressure
level
Refill the system until the
pressure is above 1 bar or
14.5 psi
Содержание VGH-100-CH
Страница 2: ......
Страница 5: ...5 E95 1901EN032 User manual Slant Fin VGH CH CO 1 SAFETY GUIDELINES...
Страница 6: ...6 E95 1901EN032 User manual Slant Fin VGH CH CO CONSIGNES DE S CURIT...
Страница 28: ...28 E95 1901EN032 User manual Slant Fin VGH CH CO...
Страница 29: ......
Страница 30: ......
Страница 31: ......