27
Installation of the Unit
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal to each
stripped wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw with a
screwdriver.(Fig.42)
(3). How to fix connection cord and power cord by cord clamp
After passing the connection cord and power cord through the insulation tube, fasten it with
the cord clamp.(Fig.43)
Solid wire
Strand wire
Solderless terminal
Insulation laver
Fig.42
Fig.41
Fig.43
Screw with
special washer
Wire
Wire
Terminal
board
Round
terminal
Round
terminal
Insulation tube
Insulation tube
Cord clamp
CAUTION!
● Before starting work, check that power is not being supplied to the indoor unit and outdoor
unit.
● Match the terminal block numbers and connection cord colors with those of the indoor unit
side.
● Erroneous wiring may cause burning of the electric parts.
● Connect the connection cords firmly to the terminal block. Imperfect installation may cause
a fire.
● Always fasten the outside covering of the connection cord with cord clamps. (If the
insulator is not clamped, electric leakage may occur.)
● Always connect the ground wire.