25
n tallation anual
5.2 Notices for Installation
Caution
1.The unit should be installed only by authorized service center according to local or government regulations and in compliance
with this manual.
2.Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service
center, the malfunction may not be solved due to incovenient contact between the user and the service personnel.
:KHQUHPRYLQJWKHXQLWWRWKHRWKHUSODFHSOHDVH¿UVWO\FRQWDFWZLWKWKHORFDODXWKRUL]HGVHUYLFHFHQWHU
4.Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
5.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is
GDPDJHGLWPXVWEHUHSODFHGE\WKHPDQXIDFWXUHULWVVHUYLFHDJHQWRUVLPLODUO\TXDOL¿HGSHUVRQVLQRUGHUWRDYRLGDKD]DUG
6.The appliance must be positioned so that the plug is accessible.
7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube.
8.The instructions shall state the substance of the following:This appliance is not intended for use by persons(including
FKLOGUHQZLWKUHGXFHGSK\VLFDOVHQVRU\RUPHQWDOFDSDELOLWLHVRUODFNRIH[SHULHQFHDQGNQRZOHGJHXQOHVVWKH\KDYHEHHQ
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
$SSOLDQFHVKDOOEHLQVWDOOHGRSHUDWHGDQGVWRUHGLQDURRPZLWKDÀRRUDUHDODUJHUWKDQ;P
2
(see table 1).
1.
:KHQLQVWDOOLQJRUUHORFDWLQJWKHXQLWEHVXUHWRNHHSWKHUHIULJHUDQWFLUFXLWIUHHIURPDLURUVXEVWDQFHVRWKHUWKDQWKH
VSHFL¿HGUHIULJHUDQW
—
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture,
resulting in injury.
2.
When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or
XQTXDOL¿HGUHIULJHUDQW
—
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or
even series safety accident.
3.
:KHQUHIULJHUDQWQHHGVWREHUHFRYHUHGGXULQJUHORFDWLQJRUUHSDLULQJWKHXQLWEHVXUHWKDWWKHXQLWLVUXQQLQJLQFRROLQJ
PRGH7KHQIXOO\FORVHWKHYDOYHDWKLJKSUHVVXUHVLGHOLTXLGYDOYH$ERXWVHFRQGVODWHUIXOO\FORVHWKHYDOYHDWORZ
pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant
recovery should not exceed 1 minute.
—
If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
4.
'XULQJUHIULJHUDQWUHFRYHU\PDNHVXUHWKDWOLTXLGYDOYHDQGJDVYDOYHDUHIXOO\FORVHGDQGSRZHULVGLVFRQQHFWHGEHIRUH
detaching the connection pipe.
—
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
5
.
:KHQLQVWDOOLQJWKHXQLWPDNHVXUHWKDWFRQQHFWLRQSLSHLVVHFXUHO\FRQQHFWHGEHIRUHWKHFRPSUHVVRUVWDUWVUXQQLQJ
—
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
6
.
3URKLELWLQVWDOOLQJWKHXQLWDWWKHSODFHZKHUHWKHUHPD\EHOHDNHGFRUURVLYHJDVRUÀDPPDEOHJDV
—
,IWKHUHOHDNHGJDVDURXQGWKHXQLWLWPD\FDXVHH[SORVLRQDQGRWKHUDFFLGHQWV
7
.
Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service
center authorized and ask for a proper electric wire.
—
3RRUFRQQHFWLRQVPD\OHDGWRHOHFWULFVKRFNRU¿UH
8
.
8VHWKHVSHFL¿HGW\SHVRIZLUHVIRUHOHFWULFDOFRQQHFWLRQVEHWZHHQWKHLQGRRUDQGRXWGRRUXQLWV)LUPO\FODPSWKHZLUHV
so that their terminals receive no external stresses.
—
(OHFWULFZLUHVZLWKLQVXI¿FLHQWFDSDFLW\ZURQJZLUHFRQQHFWLRQVDQGLQVHFXUHZLUHWHUPLQDOVPD\FDXVHHOHFWULFVKRFNRU¿UH
WARNING
7RHQVXUHVDIHW\SOHDVHEHPLQGIXORIWKHIROORZLQJSUHFDXWLRQV
5.1.6 Installation prepare
3OHDVHQRWLFHWKDWWKHXQLWLV¿OOHGZLWKÀDPPDEOHJDV5,QDSSURSULDWHWUHDWPHQWRIWKHXQLWLQYROYHV
the risk of severe damages of people andmaterial. Details to this refrigerant are found in chapter
"refrigerant".