IDP 700 Terminal Series - Hardware Guide
© SkyWave Proprietary 43 T206, Version 01
4.10 Connect to Power
CAUTION
Apply power only after
making ground connection.
CAUTION
Before applying power to the terminal, make sure that your
power supply’s rated voltage follows the recommended values
specified in Section 2.
CAUTION
The installer is responsible for complying with local electrical
codes.
CAUTION
Do not attempt an upgrade of the IDP
transceiver unit while disconnected from
the main power supply.
Note:
SkyWave recommends that if possible the user wait until the terminal is
unblocked (i.e., has a full view of the sky) before powering on the terminal.
1.
Locate the main power input and the ground (GND) wires using the connector pin
out table (Table 4 and Table 5).
You can connect the terminal ground to ground in the fuse panel or to chassis ground.
To do this, secure the ground wire on the cable assembly to a piece of metal
electrically connected to the vehicle chassis using a sheet metal screw.
2.
Ensure that the main power input and ground wires reach the vehicle fuse panel.
If the wires are not long enough, splice similar gauge wire to the main power input
and ground wires so that they reach the fuse panel. Cover any splices with adhesive
lined heat shrink.
3.
Correctly mate connectors before applying power and make sure to connect the
battery ground at the same time or before applying power. This is especially
important when the battery ground is also connected to an external RS-232 console
communication port.
4.
Connect the ground wire to the grounding point selected in Section 4.3. Check that
the polarity is correct and the voltage source is as specified in Section 3.
5.
Connect the main power input wire to the un-switched vehicle power source within
the fuse panel.
6.
Loop and secure any excess cabling.
If your application requires extended cable lengths, it is necessary to calculate the cable
voltage drop to determine if the terminal is receiving at least 9 V (with 1.7 A draw).
Large cable voltage drops may adversely affect terminal operation.
4.11 Register the Terminal
Note:
The terminals must complete registration to operate.
Once you apply power, the terminal goes into satellite search mode to acquire the
SkyWave IsatData Pro network. This activity may take a few minutes to complete. If you
experience difficulties, refer to Section 5 for troubleshooting suggestions.
Содержание IDP 700 Series
Страница 70: ...www SkyWave com ...