REV. 1/26/06
Page 4 of 9
FUNCTIONS:
1. With the slide switch in the REMOTE position, the system will only operate if
the remote receiver receives commands from the transmitter.
2.
Upon initial use or after an extended period of no use, the ON button may have to be
pressed for up to three seconds before activating servo motor. If the system
does not respond to the transmitter on initial use, see Matching Security Codes.
3.
With the slide in the OFF position, the system is off.
4.
It is suggested that the slide switch be placed in the OFF position if you will
be away from your home for an extended period of time.
5.
Placing the slide switch in the OFF position also functions as a safety "lock out"
by both turning the system OFF and rendering the transmitter inoperative.
INSTALLATION INSTRUCTIONS
WARNING
DO NOT CONNECT REMOTE RECEIVER DIRECTLY TO 110-120VAC POWER. THIS WILL BURN
OUT THE RECEIVER. FOLLOW INSTRUCTIONS FROM MANUFACTURER OF GAS VALVE FOR
CORRECT WIRING PROCEDURES. IMPROPER INSTALLATION OF ELECTRIC COMPONENTS
CAN CAUSE DAMAGE TO GAS VALVE AND REMOTE RECEIVER.
INSTALLATION
The remote receiver can be mounted on or near the fireplace hearth. PROTECTION FROM EXTREME HEAT IS VERY IMPORTANT.
Like any piece of electronic equipment, the remote receiver should be kept away from temperatures exceeding 130º F inside the
receiver case. Battery life is also significantly shortened if batteries are exposed to high temperatures.
HEARTH MOUNT
The remote receiver can be placed on the fireplace hearth or under the fireplace, behind the control
access panel. Position where the ambient temperature inside the receiver case does not exceed
130º F.
NOTE: Black Button is used on Hearth Mount Applications.
WIRING INSTRUCTIONS
CONNECTING THE RECEIVER TO A HI/LOW SERVO MOTOR STYLE VALVE SYSTEM
1.
Connect the BLACK 18 gage stranded wire with the 1/4” female terminal from the receiver to the 1/4” male terminal on the valve
servo motor.
2.
Connect the Black 18 gage stranded wire with the 7/32” female terminal from the receiver to the 7/32” male terminal on the valve
servo motor.
3.
After receiver wires are connected to the valve servo motor terminals make sure the receiver shield is located over the receiver and
then locate the receiver in an area that will not exceed the 130° F.
4.
Depending on the product that this remote control system is used on the 1/4” female terminal and wire from the receiver and the
7/32” female terminal and wire may need to be cut to a shorter length. This can be done by removing the (2) wires from the receiver
cutting them to the desired length then reinstalling them into the same connections on the receiver.
IMPORTANT NOTE:
Operation of these controls is dependent on which wire is attached to which terminal. If operation of control
does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.
NOTE
: Up to 6 VDC of power is provided at the receiver terminal.
REMOTE
OFF
Wire terminals
Remote Receiver
Receiver
Slide
Button
LEARN
ADJ.
www.FireplaceRemoteControls.com
1.877.374.4404