REV. 1/26/06
Page 2 of 9
1. DISPLAY
Indicates CURRENT room temperature
.
2.
0
F
OR
0
C
Indicates degrees Fahrenheit or Celsius.
3. FLAME
Indicates burner/valve in operation.
4. ROOM
Indicates remote is in THERMO operation.
5. TEMP
Appears during manual operation.
6. SET
Appears during time of setting the desired
temperature in the thermo operation.
SETTING
0
F /
0
C SCALE
The factory setting for temperature is
0
F
. To change this setting to
0
C,
first
•
Press the ON/HI key and the LO/OFF key on the transmitter at the
same time this will change from
0
F to
0
C. Follow this same
procedure to change from
0
C back to
0
F
.
MANUAL FUNCTION
To operate the system in the manual “MODE” do the following.
ON OPERATION
Press and hold the ON/HI key until the appliance flame comes on and
reaches the desired flame height or is at full on. During this time the
LCD screen will show HI, after 3 seconds the LCD screen will default to
display room temperature and the word TEMP will show
. (Flame icon
will appear on LCD screen in manual on mode)
OFF OPERATION
Press and hold the LO/OFF key until the appliance flame reaches the
desire flame height or completely shuts off. During this time the LCD
screen will show LO, after 3 seconds the LCD screen will default to
display room temperature and the word TEMP will show.
THERMOSTAT FUNCTION
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled when the
transmitter is in the THERMO mode (The word
ROOM must be
displayed on the screen).
To set the THERMO MODE and DESIRED
room temperature,
Press the MODE key until the LCD screen shows the word ROOM,
then the remote is in the thermostatic mode.
Press and hold the SET key until the desired set temperature is
reached. (By pressing and holding the set key the LCD screen set
numbers will increase from 45
0
to 99
0
then restart over at 45
0
) Next
release the SET key. The LCD screen will display the set temperature
for 3 seconds and the LCD screen will flash the set temperature for 3
seconds, then the LCD screen will default to display the room
temperature.
TEMP
TEMP
SET
THERMO SET
SCREEN DURING
ADJUSTING TO ON
SCREEN DURING
ADJUSTING TO OFF
TEMP
SCREEN AFTER 3
SECOND DEFAULT
ROOM
TEMP
THERMO MODE
TEMP
SCREEN AFTER 3
SECOND DEFAULT
ROOM
LCD - Liquid Crystal Display
TEMP
1
2
3
SET
4
5
6
www.FireplaceRemoteControls.com
1.877.374.4404