CAUTION

: Children and adults should be alerted to the hazards on high surface temperatures and should stay away to 

avoid burns or clothing ignition. Young children should be carefully supervised when they are in the area of the appliance.

WARNING:

 Do not use this appliance if any part has been under water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of control system and any gas control, which has been under water.

OPERATION 

SAFETY WARNINGS

 1.  Never leave the Fire Pit unattended during operation. 

 2.  Clothing or other flammable materials should not be placed on or near the appliance.   

 3.  Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the  

 

     appliance.

 4.  Installation and repair should be done by a qualified service person. The appliance should be inspected before  

 

     use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It  

 

     is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean.

 5.  Inspect the fuel supply connection before each use of the appliance.

 6.  Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply      

 

      (Natural or L.P. gas line).

WARNING

1. This appliance is 

hot

 when operated and can cause sever burns if contacted.

2.  Do not burn any solid fuels in this appliance.

INITIAL START UP

1. Turn gas ON.  Ensure you have leak tested the fire pit before operating.

2. If using the optional 120V power adapter, you must turn the switch or breaker ON. If using the standard battery   

     pack, ensure batteries are installed and the Fire Pit is ready to operate. 

3. Press the ON button on the handheld transmitter.  You will hear the ignitor probe sparking, light the gas and fire  

    pit will come on.  WARNING: Do not stand over Fire Pit during ignition or operation due to high surface tempera  

    tures. 

NOTE

: It may take several cycles of ON/OFF to purge the airflow from the gas lines.  The direct spark ignition  

 

will turn OFF after 15 seconds if the burner does not light after which you will need to press transmitter OFF button then 

back ON to initiate ignition again.  You can also bleed the gas line using the hand held remote control.  Press and hold the 

HI and LO buttons of the remote control at the same time.  This will allow the probe to spark and gas to flow to bleed the 

gas line and allow the burner to light until you release the buttons.  Afterward, start normally by pressing the ON button to 

light the fire pit.

-  There are two levels of flame height, HI and LO.  By pressing the handheld transmitter you can operate ON-OFF-HI-LO.  

The transmitter defaults to the HI setting when initially lighting the Fire Pit each time but 

will remember the last setting used and change back to the last setting in approximately 

5-seconds after lighting. 

-  Flame color adjustment can be made turning the air shutter nut under the burner pan. 

It is recommended that the nut be opened until the gas/air mixture makes a rushing 

sound (like a blow torch); then slowly closed until the rushing sound diminishes.  A desir

-

able flame is bright yellow with little or no brown at the tips.  Too yellow flame can create 
excessive sooting (See fig. 11).

To Close

Fig. 11

 Air shutter adjustment

Skytech Fire Pits

Содержание SFRSR19DSI

Страница 1: ...tion and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLTION PRECAUTION This fire pit requires a minimum 18 square inches of cross ventilation Failure to provide proper ventilation can void the warranty ...

Страница 2: ...5 8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 03 1 3 4 ...

Страница 3: ...g to Fire Pit 4 Cross Ventilation Requirements 4 Installation Into An Approved Enclosure Requirements 5 Installation of Battery Pack 6 Installation of Lava Rock Media 6 Learning the Remote to Module 7 Operation Initial Start Up 8 Replacement Parts 9 Replacement Parts List 10 Fire Pit Maintenance 11 Trouble Shooting 11 Wiring Diagram 12 Accessory Parts 13 Warranty 14 TABLE OF CONTENTS Skytech Fire ...

Страница 4: ...EV 1 6 12 Page 3 Model High Btu s Natural Propane LP Low Btu s Natural Propane LP SFRSR 19DSI 80 000 Btu s 50 000 Btu s SFRSR 25DSI 110 000 Btu s 50 000 Btu s SFRSS 20DSI 80 000 Btu s 50 000 Btu s SFRSS 26DSI 110 000 Btu s 50 000 Btu s Table 2 Btu Specifications NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures MODEL SFRS19DSI SFRS25DSI SFRSS20DSI SFRSS26DSI MINIMUM IN...

Страница 5: ...Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the system at...

Страница 6: ... fire pit should be stable and solid From the bottom of the control box that houses the gas valve and module it should be a minimum if of 4 inches to the ground level See figure 1 Drainage is critical to ensure that water does not damage and valve components Never install the fire ring system below grade 11 CAUTION A minimum of 18 square inches of cross ventilation 2 sides is required to keep the ...

Страница 7: ...nd control system should be tested before the media lava rock is installed NOTE If using optional 120V power adapter AF 4000ADP24 you must use a switch or a breaker that can be turned ON and OFF easily Normal operations are with battery power and nothing else would have to be done INSTALLATION OF BATTERY INTO TRANSMITTER You have one handheld transmitter model RCAF 3 and you will need to install t...

Страница 8: ...that the module is ready to receive a transmitter code See fig 10 4 Take the transmitter and press the OFF button You will hear a series of rapid beeps indicating the module has accepted the new code NOTE A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes pres...

Страница 9: ...nal 120V power adapter you must turn the switch or breaker ON If using the standard battery pack ensure batteries are installed and the Fire Pit is ready to operate 3 Press the ON button on the handheld transmitter You will hear the ignitor probe sparking light the gas and fire pit will come on WARNING Do not stand over Fire Pit during ignition or operation due to high surface tempera tures NOTE I...

Страница 10: ...REV 1 6 12 Page 9 REPLACEMENT PARTS 1 2 4 12 13 14 9 17 8 16 15 ON OFF HI LOW 18 SKYTECH SKYTECH SKYTECH SKYTECH 20 7 6 5 19 Skytech Fire Pits 3 ...

Страница 11: ...100 1030 11 DSI Valve Box Assembly not shown 1 ST2 010 1010 12 Stainless DSI Fire Pit Valve Box Only 1 ST3 100 1020 13 Stainless DSI Fire Pit Valve Box Cover Only 1 ST3 100 1021 14 Control Module AF 5000MOD 1 Inside valve box 1 ST3 030 1039 15 AF 4025 DSI Gas Valve 5 0 WC Natural Gas 1 ST2 080 1025 16 1 2 Flex Gas Line 24 inch Length 1 ST3 094 1001 17 Air Shutter Orifice NG 13 Used on 25 26 Fire P...

Страница 12: ...t Warn users if the pilot is not successfully ignited in 15 seconds How to Clear Press OFF then ON buttons to re attempt ignition What to Check 1 Ensure gas supply is turned on 2 Ensure that the gas line is purged of air Air is common in the gas line if the appliance has just been installed has been disconnected then re connected to the gas line or if the appliance has been unused for an extended ...

Страница 13: ...ng range 8 Make sure that there is not a large metal obstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system is in the ON position but does not sense a flame 2 Make sure that the flame sensor electrode is clean Soot buildup will insulate the electrode and...

Страница 14: ...ire pits The following accessories are available from your local Skytech dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing FCC REQUIREMENTS NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFER ENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO...

Страница 15: ... Fire Pits caused by accident misuse abuse or installation error whether performed by a contractor Service Company or owner is not covered by this warranty Modification of the Skytech product will void this warranty IN NO EVENT SHALL SKYTECH BY LIABLE FOR INCIDENTAL AND CONSEQUENTIAL INCLUD ING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRAN...

Отзывы: