MOUNTING THE REMOTE RECEIVER

HEARTH MOUNT

• 

The remote receiver can be placed on the fireplace hearth or under the fire-

place behind the control access panel.

•  MAKE SURE THAT WHERE THE RECEIVER IS PLACED DOES NOT     

EXCEED 170ºF. IT WILL CAUSE DAMAGE TO THE PRODUCT. 

• 

Use the wires attached to the remote receiver to connect to the gas valve or 

the electric module.

• 

Be sure that the connectors do not touch each other or other bare metal 

surfaces; this will cause the appliance to turn on. The connectors may be 

wrapped with electrical tape to prevent this.

WIRING INSTRUCTIONS

A qualified electrician should install the remote control system.

WIRING MILLIVOLT VALVES

INSTALLATION

Before installation make sure the remote receiver slide switch is in 

the 

OFF

 position. After installation be sure that the slide switch is 

moved to the 

REMOTE

 position.

• 

Connect one wire from the remote receiver valve connection to 

the TH terminal on the gas valve.

• 

Connect the other wire from the remote receiver valve          

connection to the TH/TP terminal on the gas valve.

MILLIVOLT SYSTEM CHECK

• 

Ensure that the pilot flame is lit.

• 

Slide the 3-position button on the remote receiver to the 

ON

     

position.  The main gas flame (i.e., the fire) should ignite. 

• 

Slide the button to 

OFF

.  The main flame should extinguish (the 

pilot flame will remain on).

• 

Slide the button to 

REMOTE

, then select 

ON

 with the mode    

button on the transmitter to change the system to on. The main 

gas flame should ignite.

WIRING ELECTRONIC SPARK IGNITIONS

Take both switch/thermostatic wires from the 

Electronic Module, and connect them to the 

receiver wires using the spade connectors.

NOTE: An adapter may be necessary 

to make the connection between the 

Electronic    Module and the Remote 

Receiver.

OFF-RE

MOTE-O

N

GROUN

D

VALVE

LEARN

CONTR

OL

FLAME

Fan Outlet Back 

Side of RX

FAN

CONTROL

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

OFF-REMOTE-ON

GROUND

VA

LV

E

FLAME CONTROL

LEARN

REMOTE

RECEIVER

FAN OUTLET

FA

N

CONTR

OL

I

S

Electronic

Module

Piggyback

Connectors

Switch

Wires

OFF-REMOTE-ON

GROUND

VA

LV

E

FLAME

CONTROL

LEARN

REMOTE 

RECEIVER

FAN 

OUTLET

FA

N

CONTR

OL

This remote control system must be installed exactly as outlined in these instructions.  Read all instructions completely before attempt-

ing installation.  Follow instructions carefully during installation.  Any modifications of this remote control or any of its components will 

void the warranty and may pose a fire hazard.

Do not connect any gas valve or electronic module directly to 110-120VAC power.  Consult gas appliance manufacturer’s instructions 

and wiring schematics for proper placement of all wires.  All electronic modules are to be wired to manufacturer’s specifications.

The following wiring diagrams are for illustration purpose only.  Follow instructions from manufacturer of gas valve and/or electronic 

module for correct wiring procedures.  Improper installation of electric components can cause damage to electronic module, gas valve 

and remote receiver.  

WARNING

Содержание RCTS-MLT-IV

Страница 1: ...de 5 Flame Indicates burner valve operational and flame height 6 Clock Indicates current time 7 Room Indicates current ROOM temperature 8 F Indicates degrees Fahrenheit C indicates degrees Celsius 9 F...

Страница 2: ...ith a flame controller Press and release the flame button to change the flame from regular to HI When the flame is switched to HI the word HI in a black box and a second flame appears in the lower rig...

Страница 3: ...e transmitter to change the system to on The main gas flame should ignite WIRING ELECTRONIC SPARK IGNITIONS Take both switch thermostatic wires from the Electronic Module and connect them to the recei...

Страница 4: ...hat the Flame Control Solenoid is disconnected from the remote receiver box 6 Screw the Solenoid on the to new regulator tower until it stops turning Then tighten the jam nut See Figure 2 7 Now take t...

Страница 5: ...until a transmitter MODE Button is pressed to reset the receiver Plug 2 or 3 prong fan cord directly into the 3 prong polarized plug on the back of the receiver see Figure 3 This receptacle output is...

Страница 6: ...tion The LEARN button in located on the front face of the receiver inside the small hole labeled LEARN Using a small screwdriver or end of a paperclip gently Press and Release the black LEARN button i...

Страница 7: ...a license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that...

Отзывы: