background image

Skytech: RCT-MLT-IV

REV. 3-26-19  Page 4

INSTALLING FLAME CONTROL SOLENOID

ALL STEPS REQUIRED FOR INSTALLATION OF THE FLAME CONTROLLER MUST BE DONE BY 

A QUALIFIED GAS SERVICE TECHNICIAN

1.  Remove the screw and knob from the variable regulator and keep in a safe place.

2.  Unscrew the nut from the regulator and keep in a safe place.

3.  Remove the bag containing a washer and blue and red plungers from the side of the flame control solenoid.

4.  Insert the correct plunger (Blue - natural gas, red - propane) into the flame control solenoid.

5.  Thread the flame control solenoid with correct plunger into the thread hole in the variable regulator.

Gas Control Valve

Variable Regulator

Washer

Flame Control

Solenoid

Variable Regulator

Plunger

Jam Nut

Solenoid

Variable Regulator

Nut

Screw

Knob

WIRING SOLENOID TO THE RECEIVER

1.  Connect the two leads from the flame control solenoid to the 

orange leads from the receiver.

2.  Plug the remote receiver into the 110/120 VAC power supply.

3.  Light the fireplace.

4.  Tighten the jam nut to the face of the variable regulator body

5.  Turn the main gas knob on the gas valve OFF.

CAUTION

TO ENSURE SAFE OPERATION, THE OUTLET PRESSURES 

ON BOTH REGULAR AND HI FLAME LEVELS SHOULD BE 

CHECKED WITH A MANOMETER IN ACCORDANCE WITH 

SPECIFICATIONS SUPPLIED BY THE VALVE 

MANUFACTURER.

OFF-RE

MOTE-O

N

GROUN

D

VALVE

LEARN

CONTR

OL

FLAME

Orange

Wires

Jam Nut

Flame Control 

Solenoid

Variable Regulator Body

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The spark electrode should begin sparking to ignite the 

pilot.  After the pilot flame is lit, the main gas valve should open and the main gas flame should ignite.

• 

Slide the button to 

OFF

.  The main gas flame and pilot flame should both extinguish.

• 

Slide the button to 

REMOTE

, then select “ON” with the mode button on the transmitter to change the system to on.  The spark 

electrode should begin sparking to ignite the pilot.  After the pilot is lit, the main gas valve should open and the main gas flame 

should ignite.

ELECTRONIC SPARK SYSTEM CHECK

Содержание RCT-MLT IV

Страница 1: ...Battery power is low replace batteries within two weeks 2 Timer Time remaining before the system shuts off must be programmed 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Set Ind...

Страница 2: ...n To turn on the fan press the FAN button on your transmitter You can switch through the various positions by pressing the fan until the desired speed is obtained Your speed options are High Medium Lo...

Страница 3: ...ceiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The main flame should extinguish the pilot flame will remain on Slide the button to REMOTE then press th...

Страница 4: ...ug the remote receiver into the 110 120 VAC power supply 3 Light the fireplace 4 Tighten the jam nut to the face of the variable regulator body 5 Turn the main gas knob on the gas valve OFF CAUTION TO...

Страница 5: ...appear on the LCD screen when childproof mode is activated CP will appear on the LCD screen if any button is pressed while childproof mode is engaged When this mode is engaged all auto settings go on...

Страница 6: ...ODIFICATIONS COULD VOID USER S AUTHORITY TO OPERATE THE EQUIPMENT FOR TECHNICAL SERVICE CALL Skytech 9230 Conservation Way Fort Wayne IN 46809 855 498 8324 Fax 888 431 0585 For Sales 888 672 8929 WEB...

Страница 7: ...tomer s compliance with all terms and conditions contained herein governing service and claims under the Warranty Skytech shall provide replacement parts at no charge for the first 5 five years of thi...

Страница 8: ...above limitation may not apply to you This warranty gives you specific rights and you may have other rights which vary from state province or nation To the extent allowable under any law the liability...

Отзывы: