Page 3
17 - REMOTE CONTROL OPERATION
F. INTITAL SET-UP
Plug Extension Module and AC Adaptor into receptacles.
Install (4) AA batteries into battery compartment of
Backup Battery Pack
, making sure batteries are installed in proper direction. Position between
valve and front of stove. A Velcro strip has been attached to help secure in place.
The
Hand Held Remote
operates on (4) AAA batteries. We recommend always using ALKALINE batteries to extend battery life and improve
operational performance.
G. GAS TYPE CONVERSION
Press and hold
Learn
Button on Main Control Module for 20 seconds. A beep will be heard letting you know the procedure has been completed.
•
If converting from NAT to LP gas: (1) one second long beep
•
If converting from LP to Nat gas: (3) three second long beep
Continue with gas type conversion by following instructions included with gas conversion kit.
H. CELSIUS/FAHRENHEIT CONVERSION
Press UP and DOWN keys simultaneously to choose Celsius or Fahrenheit.
I. IMPORTANT SAFETY FEATURE
J. CONTINUOUS PILOT FEATURE
K. CHILDPROOF FEATURE
This system has a maximum room temperature limit of 90° F (32° C) in both manual and thermostat modes. When room temperature is at or above
this point the system will shut down and the hand held remote control will read
OFF
. If you turn the system
ON
when room temperature is still at or
above this temperature, the system will again shutdown after 2 minutes when room temperature is recalculated.
Activation of this optional feature is accomplished by pressing the
MODE/SET
button and
ARROW UP
buttons simultaneously for 5 seconds. The continuous
pilot icon will appear on the
LCD
screen. Pressing
both buttons again
for 5
seconds will de-activate this feature.
This feature can also be activated via
CONTINUOUS PILOT
switch on Main
Control Module.
Activation of this optional feature is accomplished by pushing
MODE/SET
button and
ARROW DOWN
buttons simultaneously for 5 seconds.The
childproof icon
will appear on the LCS screen. When a transmitter button
is pressed the icon will flash on screen, but no signal will be transmitted.
Pressing and holding these same two buttons again for more than 5
seconds will de-activate this function.
This feature controls only manual functions of the hand held remote,
automatic functions (thermostat mode) will not be affected
.
Figure 17J
Figure 17K