background image

Skytech: 5320

REV. 7-25-18  Page 2

PM

ROOM

SET

TIMER

ONOFF

ON

OFF

THERMO

AM

LCD DISPLAY SCREEN

1

9

6

3

5

7

2

4

8

1.  BATTERY ICON

 - Battery power is low.  Replace batteries within two 

weeks.

2.  TIMER

- Indicates time remaining before system shuts OFF, when timer- 

programmed; 9-hour maximum setting. 

3.  MODE

- Indicates operation MODE of system.  ON indicates the system is 

ON, either manually or thermostatically. OFF indicates the entire system 

is turned OFF THERMO indicates the system will automatically cycle ON/

OFF, depending on programmed 

4.  SET

- Indicates desire SET room temperature for THERMO operation

5.  FLAME

 – Indicates burner/valve in operation.

6.  CLOCK

 – Indicates the current time in AM/PM

7.  ROOM

 – Indicates CURRENT room temperature.

8.  ° F

 indicates degrees Fahrenheit (ºC indicates degrees Celsius).

9.  LOCK 

– Child lock out.

OPERATION FUNCTIONS 

Note:

 Touch anyplace on the screen and the screens blue 

back light will light up and stay on 5-seconds.

To operate the system, press the MODE/SET button or 

press the MODE SECTION on the LCD screen on the front 

of the transmitter to select the operational MODE desired.

•  ON indicates the system is ON, either manually, timed 

or thermostatically.

•  THERMO indicates the system will automatically cycle 

ON/OFF, depending on programmed set temperature.

•  OFF indicates the entire system is turned OFF.

PM

ROOM

SET

TIMER

OFF

OFF

AM

OFF

MODE/SET

Mode/Set Button

NOTE:

 When setting the clock the transmitter must be in the OFF position

1.  Press the word TIMER on the LCD screen of the transmitter for more 

than two seconds.  The hour digit(s) will begin flashing.  

2.  Press the UP or DOWN buttons until the desired hour is displayed in 

AM or PM.

3.  After setting the desired hour, press and release the word TIMER 

again and the minutes digits will begin flashing.

4.  Press the UP or DOWN buttons until the desired minutes are           

displayed.  

5.  Press the word TIMER again for more than two seconds then release.  

The minute digits will cease flashing, indicating the clock has been 

successfully set.

SETTING THE CLOCK

PM

ROOM

SET

TIMER

OFF

OFF

OFF

MODE/SET

NOTE

: Flashing numbers on the display indicate the system is awaiting user input, such as using the UP and DOWN 

buttons to program a new setting.  If no change is made to flashing digits within 15 seconds, the system will complete the 

procedure last programmed and reset the display to its normal state.  

Содержание 5320

Страница 1: ...he fireplace system when a potentially unsafe condition exists PM ROOM SET TIMER OFF OFF MODE SET BATTERY COMPARTMENT BACK FRONT The transmitter operates on 4 AAA size 1 5V batteries It is recommended that ALKALINE batteries always be used for longer battery life and maximum operational performance IMPORTANT New or fully charged batteries are essential for proper operation of the multi function tr...

Страница 2: ...rational MODE desired ON indicates the system is ON either manually timed or thermostatically THERMO indicates the system will automatically cycle ON OFF depending on programmed set temperature OFF indicates the entire system is turned OFF PM ROOM SET TIMER OFF OFF AM OFF MODE SET Mode Set Button NOTE When setting the clock the transmitter must be in the OFF position 1 Press the word TIMER on the ...

Страница 3: ...MPERATURE SWING TEMPERATURE DIFFERENTIAL PM ROOM SET TIMER OFF ON The Thermo Mode on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a certain number of degrees from the SET TEMPERATURE This variation is called the SWING or TEMPERATURE DIFFERENTIAL 1 To change the temperature SWING setting 1º 3º press the TIMER and DOWN buttons simultaneously to display the current SWIN...

Страница 4: ...tery ICON on the right side of the LCD screen will appear when battery power has dropped significantly At this time approximately two weeks of battery power remains until the transmitter may experience partial or complete loss of functions PM ROOM SET TIMER OFF ON CHILDPROOF LOCK OUT CP This remote control includes a CHILDPROOF LOCK OUT feature that allows the user to LOCK OUT operation of the app...

Страница 5: ...o the receiver indicating that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a transmitter signal every 15 minutes the IC software in the RECEIVER will begin a 2 HOUR 120 minute countdown timing function If during this 2 hour period the receiver does not receive a signal from the transmitter the receiver will shut down the appliance being controlle...

Страница 6: ...illivolt gas valve without any additional relays or components The remote receiver houses the microprocessor that responds to commands from the transmitter to control system operation It emits one beep when it receives an ON or OFF command manually but no beep when cycling ON and OFF automatically in THERMO mode The remote receiver has a 3 position slide switch for selecting the MODE of operation ...

Страница 7: ...re different temperatures The remote receiver s input signals come from the transmitter Connect each of the two wires leading from the TH and TH TP terminals on the millivolt gas valve to either of the two wire terminals on the remote receiver Normally it does not matter which wires go to which terminal WIRING ELECTRONIC SPARK IGNITIONS Most electronic systems operate on a 110 VAC 24VAC power tran...

Страница 8: ...HECK MILLIVOLT VALVES Light your gas appliance following the lighting instructions that came with the appliance Confirm that the pilot flame is ON it must be in operation for the main gas valve to operate Slide the 3 position button on the remote receiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The flame should extinguish the pilot flame will remain...

Страница 9: ...kaline batteries in the SKYTECH 5320 should be at least 12 months Check and replace all batteries annually When the Transmitter no longer operates the receiver from a distance it did previously i e the transmitter s range has decreased or the remote receiver does not function at all the transmitter batteries should be checked The Transmitter should operate with as little as 5 0 volts of battery po...

Страница 10: ...range of the receiver 5 Positioning of the receiver is important If the receiver is enclosed in a metal surround the operation of the receiver may be affected as noted below Reposition the receiver to improve operating range It is suggested that a heat shield be installed to protect the receiver from extreme heat If the receiver is enclosed in a metal surround this can Cause the RF signal to get l...

Страница 11: ...stomer s compliance with all terms and conditions contained herein governing service and claims under the Warranty Skytech shall provide replacement parts at no charge for the first 5 five years of this warranty and at market cost for the Lifetime of the product to the original Customer Gas valve and gas valve components will be available at no charge for one 1 year If Skytech does not have the pa...

Страница 12: ...lasts so the above limitation may not apply to you This warranty gives you specific rights and you may have other rights which vary from state province or nation To the extent allowable under any law the liability of Skytech is limited to the express terms of this warranty and Skytech expressly disclaims any and all implied warranties including any warranties of fitness for a particular purpose or...

Отзывы: