Skytech: 3301-FSCRF
REV. 8-21-20 Page 4
SETTING THE COUNTDOWN TIMER
This remote control system can operate with a built-in countdown timer when the transmitter is in the ON or THERMO
modes only (THERMO or ON must be displayed on the screen).
1. Press and release the TIMER/TIME button on the transmitter.
The word TIMER will appear and 0:15 minutes will begin
blinking on the screen (Fig. 11).
2. Press the UP or DOWN button on the transmitter to begin
advancing through each of the countdown time options.
Available countdown times are 15 minutes, 30 minutes,
45 minutes, 1 hour, 1 hour 30 minutes, 2 hours,
2 hours 30 minutes, and each additional half-hour up to nine
(9) maximum hours.
3. To set the TIMER press the SET button on the transmitter if the
system is
ON
. It will remain ON until the time has expired. If
the system is in the THERMO mode, it will cycle on and off, as the room temperature requires until the “time” has
expired.
ROOM
SET
DOWN
UP
MODE
SET
TIME
TIMER
COVER OPEN
Fig. 11
Setting Timer
LOW BATTERY INDICATOR
A low battery icon will be visible in the upper left corner of the LCD screen when
battery power has dropped significantly (Fig. 12). At this time, approximately two weeks of
battery power remains until the transmitter may experience partial or complete loss of
functions.
ROOM
SET
Fig. 12
Low Battery Sign
CHILDPROOF “LOCK-OUT” – (CP)
This SKYTECH remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT”
operation of the appliance, from the TRANSMITTER.
SETTING “LOCK-OUT” – (CP)
1. To activate the “LOCK-OUT” feature,
press and hold
the UP
and TIMER/TIME buttons, together, for 5 seconds. The letters
CP
will appear in the TEMP frame on the LCD screen (Fig. 13).
2. To disengage the “LOCK-OUT”, press and hold the UP and
TIMER buttons, together for 5 seconds or more, and the letters
CP
will disappear from the LCD screen and the transmitter will
return to its normal operating condition.
NOTE:
If the appliance is already operating in the ON or THERMO MODES, engaging the “LOCK-OUT” will not cancel
the operating MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANSMITTER. If in the
auto modes, the THERMO operation will continue to operate normally. To totally “LOCK-OUT” the operation of the
TRANSMITTER’S operating signals; the transmitter’s MODE must be set to
OFF
.
DOWN
UP
MODE
SET
TIME
TIMER
COVER OPEN
ROOM
SET
Fig. 13
Child Protection (
CP
)