background image

This program calls back the data that was stored at "Save Data" program.
To load the data, press 

Start/Enter

 key once to blink the data number field and select 

the number using

 Inc> or <Dec

 key then press Start/Enter key for more than 3 seconds.

Select the data number to be called back.
The data matched with the number will be displayed 
at this time.

  

Loading the data.

You can inquire various information on LCD display during charging or discharging 
process. When you press

<Dec

 button the charger shows the establishment of user 

settings. And also you can monitor the voltage of individual cell by pressing 

Inc>

 button 

when the individual connection cable is linked to the Lithium battery being processed.

Start 
Enter

Start 
Enter

`>3seconds`

Load data program

Load data program

Various information during the process

The final voltage will be reached at the end of 
process.

The internal temperature of the charger and the 
temperature of battery being charged.
(The external temperature only will be displayed 
when using the thermal probe.)

The present voltage of input DC power.

DEC

DEC

DEC

DEC

DEC

INC

Using the individual connection cable to the 
battery, you can check the individual voltages of 
each cell in the battery pack. When connect the 
cable to the port on the right side of the charger 
the program shows them for maximum 8 cells in 
sequence. To utilize this feature, the battery pack 
must have output connector that linked to each 
cells.

Various information during  the process

26

27

Содержание iMax B8+

Страница 1: ...BALANCE CHARGER DISCHARGER LITHIUM BATTERY Printed in China 2009 www skyrc cn All specifications and figures are subject to change without notice B8...

Страница 2: ...control of lithium battery Discharging of lithium battery Voltage balancing and monitoring during the discharge NiMH NiCd battery program Discharging NiCd NiMH battery Charge to discharge discharge t...

Страница 3: ...e Limit The temperatureof the battery on charging will rise by its internal chemical reaction If you set the limit of temperature the process will be expired forcibly when the limit has reached Proces...

Страница 4: ...m battery Fast and Storage mode You can charge Lithium battery for special purposes Fast charge reduces the charging time of Lithium battery and Storage mode controls the final volt age of the battery...

Страница 5: ...up on a heat resistant non inflammable and non conductive surface Never place them on a car seat carpet or similar Keep all the inflammable volatile materials well away from operating area Cooling ven...

Страница 6: ...charge lead shouldbe of adequate conductorcross section And also high quality connectors normally gold contact type must be fitted to both ends Refer to the information provided by thebattery manufac...

Страница 7: ...be perceived incorrectly Toprevent the error you can set the time term to verify the cell count by the processor Normally 10 minutes are enough to perceive the cell count correctly For the battery of...

Страница 8: ...ops below the value you set the operation forcibly terminated to protect the input battery You can adjust the brightness of LCD screen at the charger INC DEC DEC INC DEC INC DEC INC INC DEC DEC INC DE...

Страница 9: ...he screen shows the present situation during charge process To stop charging press Batt type Stop key once DEC INC DEC INC Batt type stop Start Enter 3seconds Start Enter number of cells charging time...

Страница 10: ...current supplied capacity Current voltage of battery FAST charging lithium battery FAST charging lithium battery This is for charging or discharging Lithium battery not to be used for the time being T...

Страница 11: ...mode and discharge of Lithium battery pack It tries to normalize the voltage to be equal For this feature the individual plug of the battery pack should be connected to the individual port of the char...

Страница 12: ...eld is blinking The screen displays the current state of charging To stop the process press Batt type Stop key once The audiblesound indicated you the end of process DEC INC Batt type stop Start Enter...

Страница 13: ...id battery with nominal voltage from 2 to 36V Pb batteries are totally different from NiCd or NiMH batteries They can only deliver relatively lower current compare to their capacity and similar restri...

Страница 14: ...oset up the parameter value in the program press Start Enter key to make it blink then change the value with Inc or Dec key Discharging Pb battery Discharging Pb battery Save data program 13 14 15 16...

Страница 15: ...ection cable is linked to the Lithium battery being processed Start Enter Start Enter 3seconds Load data program Load data program Various information during the process The final voltage will be reac...

Страница 16: ...isplays the cause of error that is self explanatory with audible sound Warning and error messages Warning and error messages The processor detects the voltage is lower than you set at Lithium program...

Страница 17: ...declaration IMAX B8 satisfy all relevant and mandatory EC directives and For EC directives The product has been tested to meet the following technical standards FCC Part 15 Subpart B 2008 This symbol...

Страница 18: ...m Specifications Specifications Warranty and services We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational de...

Отзывы: