Initial parameter set up (Users set up)
These programs are only suitable for charging and discharging Lithium batteries with a
nominal voltage of 3.3V, 3.6V and 3.7V per cell. These batteries need to adopt different
charge technique that is termed a constant voltage (CV) and constant current (CC)
method. The charge current varies according to the battery capacity and performance.
The final voltage of charge process is also very important; it should be precisely
matched with the charade voltage of the battery. They are 4.2V for LiPo, 4.1V for Lilo,
and 3.6V for LiFe. The charge current and nominal voltage as for cell count set on the
charge program must always be correct for the battery to be charged.
When you are willing to alter the parameter value in the program, press start/enter key
to make it blink then change the value with Inc> or <Dec key. The value will be stored by
pressing start/enter key once.
Lithium battery (LiIo/LiPo/LiFe) program
Balance charging lithium battery
14
15
The left side of the first line shows the type of battery
you select at the users setting. The value on the left
side of second line sets a charge current and the
value on the right side of second line sets the voltage
of the battery pack.
After setting the current and voltage press
S
tart/Enter
key for more than 3 seconds to start the
process. (Charge current: 0.1~0.7A, Voltage: 1~8
series)
This shows the number of cells you set up and the
processor detects. "R" shows the number of cells
found by the charger and "S" is the number of cells
selected by you at the previous screen. If both
numbers are identical you can start charging by
pressing
Start/Enter
button. If not press
Batt
type/Stop
button to go back to previous screen.
Then carefully check the number of cells of the
battery pack to charge again.
The screen shows the present situation during
charge process. To stop charging press
Batt
type/Stop
key once.
DEC INC
DEC INC
Batt type
stop
Start
Enter
`>3seconds`
Start
Enter
number
of
cells
charging
time
charge
current
battery
voltage
charged
capacity
Charging of lithium battery
This charging mode is for charging Li-Po/Ion/Fe battery without balance lead.
The left side of the first line shows the type of battery
you select at the users setting. The value on the left
side of second line sets a charge current and the
value on the right side of second line sets the voltage
of the battery pack.
After setting the current and voltage press
S
tart/Enter
key for more than 3 seconds to start the
process. (Charge current: 0.1~0.7A, Voltage: 1~8
series)
This shows the number of cells you set up and the
processor detects. "R" shows the number of cells
found by the charger and "S" is the number of cells
selected by you at the previous screen. If both
numbers are identical you can start charging by
pressing
Start/Enter
button. If not press
Batt
type/Stop
button to go back to previous screen.
Then carefully check the number of cells of the
battery pack to charge again.
The screen shows the present situation during
charge process. To stop charging press
Batt
type/Stop
key once.
DEC INC
DEC INC
Batt type
stop
Start
Enter
`>3seconds`
Start
Enter
number
of
cells
charging
time
charge
current
battery
voltage
charged
capacity
LiPo BALANCE
2.0A 11.1V(3S)
This function is for balancing the voltage of Lithium-polymer battery cells while charging.
In the balance mode, the battery needs to have a balance lead to connect to the individual
balance port at the right side of the charger. And you need to connect the battery's power
lead to the output of charger. Charging in this mode is different from the normal modes,
because the built-in processor monitors voltage of individual cell and control input current
fed into each cell to equalized voltage of individual cell.
Balance charging of lithium battery